CVE-2024-4252 (GCVE-0-2024-4252)

Vulnerability from cvelistv5 – Published: 2024-04-27 13:31 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda i22 formSetUrlFilterRule stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda i22 Affected: 1.0.0.3(4687)
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "i22_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.3\\(4687\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4252",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-30T19:51:45.729808Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T17:43:07.157Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:53.167Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.262143"
          },
          {
            "name": "VDB-262143 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.262143"
          },
          {
            "name": "Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.319840"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "i22",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.3(4687)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda i22 1.0.0.3(4687) entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formSetUrlFilterRule. Mit der Manipulation des Arguments groupIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-27T13:31:04.906Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.262143"
        },
        {
          "name": "VDB-262143 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.262143"
        },
        {
          "name": "Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.319840"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-26T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-26T14:46:27.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda i22 formSetUrlFilterRule stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4252",
    "datePublished": "2024-04-27T13:31:04.906Z",
    "dateReserved": "2024-04-26T12:40:45.945Z",
    "dateUpdated": "2024-08-01T20:33:53.167Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad ha sido encontrada en Tenda i22 1.0.0.3(4687) y clasificada como cr\\u00edtica. Esto afecta a la funci\\u00f3n formSetUrlFilterRule. La manipulaci\\u00f3n del argumento groupIndex conduce a un desbordamiento de b\\u00fafer en la regi\\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El identificador asociado de esta vulnerabilidad es VDB-262143. NOTA: Se contact\\u00f3 primeramente con el proveedor sobre esta divulgaci\\u00f3n, pero no respondi\\u00f3 de ninguna manera.\"}]",
      "id": "CVE-2024-4252",
      "lastModified": "2024-11-21T09:42:28.720",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2024-04-27T14:15:07.067",
      "references": "[{\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?ctiid.262143\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?id.262143\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?submit.319840\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?ctiid.262143\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?id.262143\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?submit.319840\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-4252\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-04-27T14:15:07.067\",\"lastModified\":\"2025-01-27T18:27:19.633\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad ha sido encontrada en Tenda i22 1.0.0.3(4687) y clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formSetUrlFilterRule. La manipulaci\u00f3n del argumento groupIndex conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El identificador asociado de esta vulnerabilidad es VDB-262143. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\\\(4687\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F879BB6-4F6E-4E81-A24A-3037DBD1A5B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:i22:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52D94207-DFC8-478C-BA6B-F0A64BBB3E67\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://vuldb.com/?ctiid.262143\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.262143\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.319840\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://vuldb.com/?ctiid.262143\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.262143\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.319840\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.262143\", \"name\": \"VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.262143\", \"name\": \"VDB-262143 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?submit.319840\", \"name\": \"Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md\", \"tags\": [\"related\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:33:53.167Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-4252\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-30T19:51:45.729808Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\\\(4687\\\\):*:*:*:*:*:*:*\"], \"vendor\": \"tenda\", \"product\": \"i22_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.0.3\\\\(4687\\\\)\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-04-30T19:52:24.872Z\"}}], \"cna\": {\"title\": \"Tenda i22 formSetUrlFilterRule stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"yhryhryhr_tu (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"i22\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.0.3(4687)\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-04-26T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-04-26T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-04-26T14:46:27.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.262143\", \"name\": \"VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.262143\", \"name\": \"VDB-262143 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.319840\", \"name\": \"Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md\", \"tags\": [\"related\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Tenda i22 1.0.0.3(4687) entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formSetUrlFilterRule. Mit der Manipulation des Arguments groupIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-04-27T13:31:04.906Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-4252\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T20:33:53.167Z\", \"dateReserved\": \"2024-04-26T12:40:45.945Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-04-27T13:31:04.906Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…