Summary
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-46892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:21:05.449383Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T14:21:32.457Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SINEC INS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0 SP2 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-613",
              "description": "CWE-613: Insufficient Session Expiration",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T12:49:44.470Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-46892",
    "datePublished": "2024-11-12T12:49:44.470Z",
    "dateReserved": "2024-09-12T11:24:19.243Z",
    "dateUpdated": "2024-11-12T14:21:32.457Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-46892\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-11-12T13:15:09.940\",\"lastModified\":\"2024-11-13T23:13:06.400\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC INS (todas las versiones \u0026lt; V1.0 SP2 Update 3). La aplicaci\u00f3n afectada no invalida correctamente las sesiones cuando se elimina o deshabilita el usuario asociado o se modifican sus permisos. Esto podr\u00eda permitir que un atacante autenticado contin\u00fae realizando acciones maliciosas incluso despu\u00e9s de que se haya deshabilitado su cuenta de usuario.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-613\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0\",\"matchCriteriaId\":\"C89891C1-DFD7-4E1F-80A9-7485D86A15B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4664B195-AF14-4834-82B3-0B2C98020EB6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"75BC588E-CDF0-404E-AD61-02093A1DF343\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"A334F7B4-7283-4453-BAED-D2E01B7F8A6E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6BEA71C-CA81-4B5D-A688-2B21E62DC351\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B405F22-5517-49F5-A7CA-1E50D58DFC75\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-915275.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.