cve-2024-51765
Vulnerability from cvelistv5
Published
2024-11-15 21:42
Modified
2024-11-19 16:23
Severity ?
EPSS score ?
Summary
A security vulnerability has been identified in HPE Cray Data Virtualization Service (DVS). Depending on configuration, this vulnerability may lead to local/cluster unauthorized access.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:hpe:cray_system_management_software:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "cray_system_management_software", "vendor": "hpe", "versions": [ { "lessThan": "COS-2.5.146", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "COS 23.11.1", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "CLE 7.0.UP04.PS19", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-51765", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-19T16:15:09.759647Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276 Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-19T16:23:52.392Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "affected", "product": "Cray System Management Software", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThan": "COS-2.5.146, COS 23.11.1, CLE 7.0.UP04.PS19", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A security vulnerability has been identified in HPE Cray Data Virtualization Service (DVS). Depending on configuration, this vulnerability may lead to local/cluster unauthorized access." } ], "providerMetadata": { "dateUpdated": "2024-11-15T21:42:37.775Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbcr04748en_us\u0026docLocale=en_US" } ], "x_generator": { "engine": "cveClient/1.0.15" } } }, "cveMetadata": { "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0", "assignerShortName": "hpe", "cveId": "CVE-2024-51765", "datePublished": "2024-11-15T21:42:37.775Z", "dateReserved": "2024-11-01T14:42:12.298Z", "dateUpdated": "2024-11-19T16:23:52.392Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-51765\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2024-11-15T22:15:16.090\",\"lastModified\":\"2024-11-19T17:35:16.103\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A security vulnerability has been identified in HPE Cray Data Virtualization Service (DVS). Depending on configuration, this vulnerability may lead to local/cluster unauthorized access.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad de seguridad en HPE Cray Data Virtualization Service (DVS). Seg\u00fan la configuraci\u00f3n, esta vulnerabilidad puede provocar un acceso no autorizado a nivel local o de cl\u00faster.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbcr04748en_us\u0026docLocale=en_US\",\"source\":\"security-alert@hpe.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.