CVE-2024-6436 (GCVE-0-2024-6436)
Vulnerability from cvelistv5 – Published: 2024-09-27 19:45 – Updated: 2024-10-03 13:56
VLAI?
Title
Rockwell Automation Input Validation Vulnerability exists in the SequenceManager™ Server
Summary
An input validation vulnerability exists in the Rockwell Automation Sequence Manager™ which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | SequenceManager™ |
Affected:
<2.0
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sequencemanager",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6436",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-03T13:54:44.194684Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-03T13:56:51.490Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SequenceManager\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c2.0"
}
]
}
],
"datePublic": "2024-09-27T19:36:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAdditionally, if exploited, there could be a loss of view for the downstream equipment sequences in the c\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eontroller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\u003c/span\u003e"
}
],
"value": "An input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-27T19:45:04.984Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cul\u003e\u003cli\u003eCorrected in versions v2.0 or later.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\n\n\u003cp\u003eUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "* Corrected in versions v2.0 or later.\u00a0\n * \n\nUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "1679",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation Input Validation Vulnerability exists in the SequenceManager\u2122 Server",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-6436",
"datePublished": "2024-09-27T19:45:04.984Z",
"dateReserved": "2024-07-01T21:06:42.745Z",
"dateUpdated": "2024-10-03T13:56:51.490Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"An input validation vulnerability exists in the Rockwell Automation Sequence Manager\\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de validaci\\u00f3n de entrada en Rockwell Automation Sequence Manager\\u2122 que podr\\u00eda permitir que un usuario malintencionado env\\u00ede paquetes malformados al servidor y provoque una condici\\u00f3n de denegaci\\u00f3n de servicio. Si se explota, el dispositivo dejar\\u00eda de responder y ser\\u00eda necesario reiniciarlo manualmente para recuperarlo. Adem\\u00e1s, si se explota, podr\\u00eda perderse la vista de las secuencias de equipos posteriores en el controlador. Los usuarios no podr\\u00edan ver el estado ni ordenar las secuencias de equipos, pero la secuencia de equipos seguir\\u00eda ejecut\\u00e1ndose sin interrupciones.\"}]",
"id": "CVE-2024-6436",
"lastModified": "2024-09-30T12:45:57.823",
"metrics": "{\"cvssMetricV40\": [{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"HIGH\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}]}",
"published": "2024-09-27T20:15:06.043",
"references": "[{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html\", \"source\": \"PSIRT@rockwellautomation.com\"}]",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-6436\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-09-27T20:15:06.043\",\"lastModified\":\"2025-10-22T20:29:10.850\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de validaci\u00f3n de entrada en Rockwell Automation Sequence Manager\u2122 que podr\u00eda permitir que un usuario malintencionado env\u00ede paquetes malformados al servidor y provoque una condici\u00f3n de denegaci\u00f3n de servicio. Si se explota, el dispositivo dejar\u00eda de responder y ser\u00eda necesario reiniciarlo manualmente para recuperarlo. Adem\u00e1s, si se explota, podr\u00eda perderse la vista de las secuencias de equipos posteriores en el controlador. Los usuarios no podr\u00edan ver el estado ni ordenar las secuencias de equipos, pero la secuencia de equipos seguir\u00eda ejecut\u00e1ndose sin interrupciones.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.0\",\"matchCriteriaId\":\"451FED36-BF02-4149-81BA-28B3C6BB2D89\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-6436\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-03T13:54:44.194684Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"sequencemanager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-03T13:56:45.951Z\"}}], \"cna\": {\"title\": \"Rockwell Automation Input Validation Vulnerability exists in the SequenceManager\\u2122 Server\", \"source\": {\"advisory\": \"1679\", \"discovery\": \"INTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-153\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-153 Input Data Manipulation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"SequenceManager\\u2122\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003c2.0\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"* Corrected in versions v2.0 or later.\\u00a0\\n * \\n\\nUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\\n\\n\\u00b7 \\u00a0 \\u00a0 \\u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cul\u003e\u003cli\u003eCorrected in versions v2.0 or later.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\\n\\n\u003cp\u003eUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u003c/p\u003e\u003cp\u003e\\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\\\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\\n\\n\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"datePublic\": \"2024-09-27T19:36:00.000Z\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An input validation vulnerability exists in the Rockwell Automation Sequence Manager\\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eAn input validation vulnerability exists in the Rockwell Automation Sequence Manager\\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. \u003c/span\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eAdditionally, if exploited, there could be a loss of view for the downstream equipment sequences in the c\u003c/a\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eontroller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2024-09-27T19:45:04.984Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-6436\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-03T13:56:51.490Z\", \"dateReserved\": \"2024-07-01T21:06:42.745Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2024-09-27T19:45:04.984Z\", \"assignerShortName\": \"Rockwell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…