cve-2024-9002
Vulnerability from cvelistv5
Published
2024-10-11 13:43
Modified
2024-10-11 14:03
Severity ?
EPSS score ?
Summary
CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized
access, loss of confidentiality, integrity, and availability of the workstation when non-admin
authenticated user tries to perform privilege escalation by tampering with the binaries
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Schneider Electric | Easergy Studio |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:easergy_studio:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "easergy_studio", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-9002", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-11T14:00:52.423687Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-11T14:03:06.738Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Easergy Studio", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Versions 9.3.1 and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity, and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries" } ], "value": "CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity, and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-269", "description": "CWE-269 Improper Privilege Management", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-11T13:43:25.391Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-03.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-9002", "datePublished": "2024-10-11T13:43:25.391Z", "dateReserved": "2024-09-19T14:23:12.585Z", "dateUpdated": "2024-10-11T14:03:06.738Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-9002\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-10-11T14:15:06.397\",\"lastModified\":\"2024-10-15T12:58:51.050\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\\naccess, loss of confidentiality, integrity, and availability of the workstation when non-admin\\nauthenticated user tries to perform privilege escalation by tampering with the binaries\"},{\"lang\":\"es\",\"value\":\"CWE-269: Existe una vulnerabilidad de administraci\u00f3n inadecuada de privilegios que podr\u00eda causar acceso no autorizado, p\u00e9rdida de confidencialidad, integridad y disponibilidad de la estaci\u00f3n de trabajo cuando un usuario autenticado que no es administrador intenta realizar una escalada de privilegios alterando los binarios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-03.pdf\",\"source\":\"cybersecurity@se.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.