GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2025-12896 (GCVE-0-2025-12896)

Vulnerability from cvelistv5 – Published: 2025-11-07 20:24 – Updated: 2025-11-07 20:40
VLAI
Summary
Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-07 20:39 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Impacted products
Vendor Product Version CPE status
Solidigm™ D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336 Affected: All FW prior to ACV10360
Affected: All FW prior to JCV10501
Affected: All FW prior to 9CV10490
Affected: All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)
Affected: All FW prior to 5CV10326
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12896",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-07T20:39:53.655558Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-07T20:40:07.108Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336",
          "vendor": "Solidigm\u2122",
          "versions": [
            {
              "status": "affected",
              "version": "All FW prior to ACV10360"
            },
            {
              "status": "affected",
              "version": "All FW prior to JCV10501"
            },
            {
              "status": "affected",
              "version": "All FW prior to 9CV10490"
            },
            {
              "status": "affected",
              "version": "All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)"
            },
            {
              "status": "affected",
              "version": "All FW prior to 5CV10326"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-114",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-114 Authentication Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-07T20:24:11.186Z",
        "orgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
        "shortName": "Solidigm"
      },
      "references": [
        {
          "url": "https://www.solidigm.com/support-page/support-security.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
    "assignerShortName": "Solidigm",
    "cveId": "CVE-2025-12896",
    "datePublished": "2025-11-07T20:24:11.186Z",
    "dateReserved": "2025-11-07T18:56:03.627Z",
    "dateUpdated": "2025-11-07T20:40:07.108Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-12896",
      "date": "2026-09-17",
      "epss": "0.00121",
      "percentile": "0.022"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-12896\",\"sourceIdentifier\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"published\":\"2025-11-07T21:15:40.750\",\"lastModified\":\"2026-06-17T08:33:09.943\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\"}],\"affected\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"affectedData\":[{\"vendor\":\"Solidigm\u2122\",\"product\":\"D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"All FW prior to ACV10360\",\"status\":\"affected\"},{\"version\":\"All FW prior to JCV10501\",\"status\":\"affected\"},{\"version\":\"All FW prior to 9CV10490\",\"status\":\"affected\"},{\"version\":\"All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)\",\"status\":\"affected\"},{\"version\":\"All FW prior to 5CV10326\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-11-07T20:39:53.655558Z\",\"id\":\"CVE-2025-12896\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-307\"}]}],\"references\":[{\"url\":\"https://www.solidigm.com/support-page/support-security.html\",\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\"}]}}",
    "redhat_vex": {
      "current_release_date": "2025-11-10T12:22:41+00:00",
      "cve": "CVE-2025-12896",
      "id": "CVE-2025-12896",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2025-12896",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-12896.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-12896\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-11-07T20:39:53.655558Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-11-07T20:39:58.336Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-114\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-114 Authentication Abuse\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.4, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Solidigm\\u2122\", \"product\": \"D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336\", \"versions\": [{\"status\": \"affected\", \"version\": \"All FW prior to ACV10360\"}, {\"status\": \"affected\", \"version\": \"All FW prior to JCV10501\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 9CV10490\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 5CV10326\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.solidigm.com/support-page/support-security.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eImproper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\u003c/span\u003e\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-307\", \"description\": \"CWE-307 Improper Restriction of Excessive Authentication Attempts\"}]}], \"providerMetadata\": {\"orgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"shortName\": \"Solidigm\", \"dateUpdated\": \"2025-11-07T20:24:11.186Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-12896\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-07T20:40:07.108Z\", \"dateReserved\": \"2025-11-07T18:56:03.627Z\", \"assignerOrgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"datePublished\": \"2025-11-07T20:24:11.186Z\", \"assignerShortName\": \"Solidigm\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…