CVE-2025-24936 (GCVE-0-2025-24936)

Vulnerability from cvelistv5 – Published: 2025-07-21 06:27 – Updated: 2025-07-23 18:45
VLAI?
Summary
The web application allows user input to pass unfiltered to a command executed on the underlying operating system. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. An attacker with low privileged access to the application has the potential to execute commands on the operating system under the context of the webserver.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Nokia WaveSuite NOC Affected: WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12
Unaffected: WS-NOC 24.6 FP3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-24936",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T18:45:19.086277Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T18:45:22.589Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WaveSuite NOC",
          "vendor": "Nokia",
          "versions": [
            {
              "status": "affected",
              "version": "WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12"
            },
            {
              "status": "unaffected",
              "version": "WS-NOC 24.6 FP3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web application allows user input to pass unfiltered to a command executed on the underlying operating system. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet.\n\nAn attacker with low privileged access to the application has the potential to execute commands on the operating system under the context of the webserver."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T06:27:46.093Z",
        "orgId": "b48c3b8f-639e-4c16-8725-497bc411dad0",
        "shortName": "Nokia"
      },
      "references": [
        {
          "name": "Nokia Security Advisory",
          "url": "https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24936/"
        }
      ],
      "title": "Insufficient Validation of Input in the URL",
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b48c3b8f-639e-4c16-8725-497bc411dad0",
    "assignerShortName": "Nokia",
    "cveId": "CVE-2025-24936",
    "datePublished": "2025-07-21T06:27:46.093Z",
    "dateReserved": "2025-01-29T07:19:18.312Z",
    "dateUpdated": "2025-07-23T18:45:22.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-24936\",\"sourceIdentifier\":\"b48c3b8f-639e-4c16-8725-497bc411dad0\",\"published\":\"2025-07-21T07:15:23.890\",\"lastModified\":\"2025-08-11T14:52:51.543\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The web application allows user input to pass unfiltered to a command executed on the underlying operating system. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet.\\n\\nAn attacker with low privileged access to the application has the potential to execute commands on the operating system under the context of the webserver.\"},{\"lang\":\"es\",\"value\":\"La aplicaci\u00f3n web permite que la entrada del usuario se transmita sin filtrar a un comando que se ejecuta en el sistema operativo subyacente. El componente vulnerable est\u00e1 vinculado a la pila de red y el conjunto de posibles atacantes se extiende a toda Internet. Un atacante con acceso con pocos privilegios a la aplicaci\u00f3n tiene el potencial de ejecutar comandos en el sistema operativo en el contexto del servidor web.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:nokia:wavesuite_noc:23.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"557A2709-02CD-41F2-8D39-591C55DBC6CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:nokia:wavesuite_noc:23.12:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3A4BF10D-5F41-49B7-AF3F-BAC85C6D8A15\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:nokia:wavesuite_noc:24.6:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"9CA0E502-BCDA-4616-A4D2-0DBBC22163DA\"}]}]}],\"references\":[{\"url\":\"https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24936/\",\"source\":\"b48c3b8f-639e-4c16-8725-497bc411dad0\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-24936\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-23T18:45:19.086277Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-23T18:45:11.384Z\"}}], \"cna\": {\"title\": \"Insufficient Validation of Input in the URL\", \"affected\": [{\"vendor\": \"Nokia\", \"product\": \"WaveSuite NOC\", \"versions\": [{\"status\": \"affected\", \"version\": \"WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12\"}, {\"status\": \"unaffected\", \"version\": \"WS-NOC 24.6 FP3\"}]}], \"references\": [{\"url\": \"https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24936/\", \"name\": \"Nokia Security Advisory\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The web application allows user input to pass unfiltered to a command executed on the underlying operating system. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet.\\n\\nAn attacker with low privileged access to the application has the potential to execute commands on the operating system under the context of the webserver.\"}], \"providerMetadata\": {\"orgId\": \"b48c3b8f-639e-4c16-8725-497bc411dad0\", \"shortName\": \"Nokia\", \"dateUpdated\": \"2025-07-21T06:27:46.093Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-24936\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-23T18:45:22.589Z\", \"dateReserved\": \"2025-01-29T07:19:18.312Z\", \"assignerOrgId\": \"b48c3b8f-639e-4c16-8725-497bc411dad0\", \"datePublished\": \"2025-07-21T06:27:46.093Z\", \"assignerShortName\": \"Nokia\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…