CVE-2025-31930 (GCVE-0-2025-31930)

Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-05-13 14:46
VLAI?
Summary
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CWE
  • CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
Impacted products
Vendor Product Version
Siemens IEC 1Ph 7.4kW Child socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Child socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Parent cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Parent cable 7m incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Parent socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Parent socket incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Parent socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 1Ph 7.4kW Parent socket/ shutter SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Child cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Child socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Child socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Parent cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Parent cable 7m incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Parent socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Parent socket incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Parent socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC 3Ph 22kW Parent socket/ shutter SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC ERK 3Ph 22 kW Child cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC ERK 3Ph 22 kW Child cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC ERK 3Ph 22 kW Child cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC ERK 3Ph 22 kW Child socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC ERK 3Ph 22 kW Parent socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens IEC ERK 3Ph 22 kW Parent socket incl. SI Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Cellular 48A NTEP Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Child 40A w/ 15118 HW Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Child 48A BA Compliant Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Child 48A w/ 15118 HW Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 40A with Simcard Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A (USPS) Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A BA Compliant Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A with Simcard BA Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A, 15118, 25ft Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A, 15118, 25ft Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A, 15118, 25ft Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens UL Commercial Parent 48A,15118 25ft Sim Affected: 0 , < V2.135 (custom)
Create a notification for this product.
    Siemens VersiCharge Blue™ 80A AC Cellular Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31930",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-13T14:18:38.660134Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-13T14:46:55.188Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Child socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Child socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent cable 7m incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket/ shutter SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Child socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Child socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent cable 7m incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket/ shutter SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Parent socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Parent socket incl. SI",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Cellular 48A NTEP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Child 40A w/ 15118 HW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Child 48A BA Compliant",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Child 48A w/ 15118 HW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 40A with Simcard",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A (USPS)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A BA Compliant",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A with Simcard BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A, 15118, 25ft",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A, 15118, 25ft",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A, 15118, 25ft",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A,15118 25ft Sim",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "VersiCharge Blue\u2122 80A AC Cellular",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions \u003c V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions \u003c V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions \u003c V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions \u003c V2.135), VersiCharge Blue\u2122 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions \u003c V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188: Initialization of a Resource with an Insecure Default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-13T09:38:43.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-556937.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31930",
    "datePublished": "2025-05-13T09:38:43.000Z",
    "dateReserved": "2025-04-01T16:45:21.675Z",
    "dateUpdated": "2025-05-13T14:46:55.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-31930\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-05-13T10:15:24.710\",\"lastModified\":\"2025-05-13T19:35:18.080\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions \u003c V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions \u003c V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions \u003c V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions \u003c V2.135), VersiCharge Blue\u2122 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions \u003c V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en el z\u00f3calo secundario IEC 1Ph 7.4kW (8EM1310-2EH04-0GA0) (Todas las versiones \u0026lt; V2.135), z\u00f3calo/obturador secundario IEC 1Ph 7.4kW (8EM1310-2EN04-0GA0) (Todas las versiones \u0026lt; V2.135), cable principal IEC 1Ph 7.4kW de 7 m (8EM1310-2EJ04-3GA1) (Todas las versiones \u0026lt; V2.135), cable principal IEC 1Ph 7.4kW de 7 m incl. SIM (8EM1310-2EJ04-3GA2) (Todas las versiones \u0026lt; V2.135), z\u00f3calo principal IEC 1Ph 7.4kW (8EM1310-2EH04-3GA1) (Todas las versiones \u0026lt; V2.135), z\u00f3calo principal IEC 1Ph 7.4kW incl. SIM (8EM1310-2EH04-3GA2) (Todas las versiones \u0026lt; V2.135), Toma principal/obturador IEC monof\u00e1sico de 7,4 kW (8EM1310-2EN04-3GA1) (Todas las versiones \u0026lt; V2.135), Toma principal/obturador IEC monof\u00e1sico de 7,4 kW SIM (8EM1310-2EN04-3GA2) (Todas las versiones \u0026lt; V2.135), Cable secundario IEC trif\u00e1sico de 22 kW de 7 m (8EM1310-3EJ04-0GA0) (Todas las versiones \u0026lt; V2.135), Toma secundaria IEC trif\u00e1sica de 22 kW (8EM1310-3EH04-0GA0) (Todas las versiones \u0026lt; V2.135), Toma secundaria IEC trif\u00e1sica de 22 kW (8EM1310-3EN04-0GA0) (Todas las versiones \u0026lt; V2.135), Toma secundaria IEC trif\u00e1sica de 22 kW (8EM1310-3EN04-0GA0) (Todas las versiones \u0026lt; V2.135), cable principal IEC 3Ph 22kW de 7 m (8EM1310-3EJ04-3GA1) (todas las versiones \u0026lt; V2.135), cable principal IEC 3Ph 22kW de 7 m incl. SIM (8EM1310-3EJ04-3GA2) (todas las versiones \u0026lt; V2.135), toma principal IEC 3Ph 22kW (8EM1310-3EH04-3GA1) (todas las versiones \u0026lt; V2.135), toma principal IEC 3Ph 22kW incl. SIM (8EM1310-3EH04-3GA2) (Todas las versiones \u0026lt; V2.135), Toma principal/obturador IEC 3Ph 22kW (8EM1310-3EN04-3GA1) (Todas las versiones \u0026lt; V2.135), Toma principal/obturador IEC 3Ph 22kW SIM (8EM1310-3EN04-3GA2) (Todas las versiones \u0026lt; V2.135), Cable secundario IEC ERK 3Ph 22 kW 7 m (8EM1310-3FJ04-0GA0) (Todas las versiones \u0026lt; V2.135), Cable secundario IEC ERK 3Ph 22 kW 7 m (8EM1310-3FJ04-0GA1) (Todas las versiones \u0026lt; V2.135), Cable secundario IEC ERK 3Ph 22 kW 7 m (8EM1310-3FJ04-0GA2) (Todas las versiones \u0026lt; V2.135), V2.135), toma de corriente secundaria IEC ERK 3Ph de 22 kW (8EM1310-3FH04-0GA0) (todas las versiones \u0026lt; V2.135), toma de corriente principal IEC ERK 3Ph de 22 kW (8EM1310-3FH04-3GA1) (todas las versiones \u0026lt; V2.135), toma de corriente principal IEC ERK 3Ph de 22 kW incl. SI (8EM1310-3FH04-3GA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Child 40A con hardware 15118 (8EM1310-4CF14-0GA0) (Todas las versiones \u0026lt; V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (Todas las versiones \u0026lt; V2.135), UL Commercial Child 48A con hardware 15118 (8EM1310-5CF14-0GA0) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 40A con tarjeta SIM (8EM1310-4CF14-1GA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 48A con Simcard BA (8EM1310-5CF14-1GA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 48A, 15118, 25 pies (8EM1310-5CG14-1GA1) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 48A, 15118, 25 pies (8EM1314-5CG14-2FA2) (Todas las versiones \u0026lt; V2.135), UL Commercial Parent 48A, 15118, 25 pies (8EM1315-5HG14-1GA2) (Todas las versiones anteriores a la V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (Todas las versiones anteriores a la V2.135), VersiCharge Blue\u2122 80A AC Cellular (8EM1315-7BG16-1FH2) (Todas las versiones anteriores a la V2.135). Los dispositivos afectados tienen el servicio Modbus habilitado por defecto. Esto podr\u00eda permitir que un atacante conectado a la misma red controle remotamente el cargador de veh\u00edculos el\u00e9ctricos.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"LOW\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1188\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-556937.html\",\"source\":\"productcert@siemens.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-31930\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-13T14:18:38.660134Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-13T14:40:21.936Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Child socket\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Child socket/ shutter\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Parent cable 7m\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Parent cable 7m incl. SIM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Parent socket\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Parent socket incl. SIM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Parent socket/ shutter\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 1Ph 7.4kW Parent socket/ shutter SIM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Child cable 7m\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Child socket\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Child socket/ shutter\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Parent cable 7m\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Parent cable 7m incl. SIM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Parent socket\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Parent socket incl. SIM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Parent socket/ shutter\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC 3Ph 22kW Parent socket/ shutter SIM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC ERK 3Ph 22 kW Child cable 7m\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC ERK 3Ph 22 kW Child cable 7m\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC ERK 3Ph 22 kW Child cable 7m\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC ERK 3Ph 22 kW Child socket\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC ERK 3Ph 22 kW Parent socket\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"IEC ERK 3Ph 22 kW Parent socket incl. SI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Cellular 48A NTEP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Child 40A w/ 15118 HW\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Child 48A BA Compliant\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Child 48A w/ 15118 HW\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 40A with Simcard\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A (USPS)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A BA Compliant\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A with Simcard BA\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A, 15118, 25ft\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A, 15118, 25ft\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A, 15118, 25ft\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"UL Commercial Parent 48A,15118 25ft Sim\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"VersiCharge Blue\\u2122 80A AC Cellular\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.135\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-556937.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions \u003c V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions \u003c V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions \u003c V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions \u003c V2.135), VersiCharge Blue\\u2122 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions \u003c V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1188\", \"description\": \"CWE-1188: Initialization of a Resource with an Insecure Default\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-05-13T09:38:43.000Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-31930\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-13T14:46:55.188Z\", \"dateReserved\": \"2025-04-01T16:45:21.675Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2025-05-13T09:38:43.000Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…