CVE-2025-3499 (GCVE-0-2025-3499)

Vulnerability from cvelistv5 – Published: 2025-07-09 08:57 – Updated: 2025-07-09 13:08
VLAI?
Summary
The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary commands that are executed with administrative permissions by the underlying operating system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command (’OS Command Injection’)
Assigner
References
Impacted products
Vendor Product Version
Radiflow iSAP Smart Collector Affected: 1.20 , < 3.02-1 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3499",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T13:06:55.487400Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-09T13:08:05.257Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "iSAP Smart Collector",
          "vendor": "Radiflow",
          "versions": [
            {
              "lessThan": "3.02-1",
              "status": "affected",
              "version": "1.20",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\nThe device has two web servers that expose unauthenticated REST APIs on the management network (TCP\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\ncommands that are executed with administrative permissions by the underlying operating system.\u003cbr\u003e\u003c/span\u003e"
            }
          ],
          "value": "The device has two web servers that expose unauthenticated REST APIs on the management network (TCP\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\ncommands that are executed with administrative permissions by the underlying operating system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u2019OS Command Injection\u2019)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-09T08:57:26.893Z",
        "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "shortName": "ENISA"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2025-3499"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unauthenticated execution of arbitrary commands in Radiflow iSAP Smart Collector",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
    "assignerShortName": "ENISA",
    "cveId": "CVE-2025-3499",
    "datePublished": "2025-07-09T08:57:26.893Z",
    "dateReserved": "2025-04-10T08:40:15.892Z",
    "dateUpdated": "2025-07-09T13:08:05.257Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-3499\",\"sourceIdentifier\":\"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158\",\"published\":\"2025-07-09T09:15:27.297\",\"lastModified\":\"2025-07-10T13:17:30.017\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The device has two web servers that expose unauthenticated REST APIs on the management network (TCP\\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\\ncommands that are executed with administrative permissions by the underlying operating system.\"},{\"lang\":\"es\",\"value\":\"El dispositivo cuenta con dos servidores web que exponen API REST no autenticadas en la red de administraci\u00f3n (puertos TCP 8084 y 8086). Al aprovechar la inyecci\u00f3n de comandos del sistema operativo a trav\u00e9s de estas API, un atacante puede enviar comandos arbitrarios que el sistema operativo subyacente ejecuta con permisos administrativos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://www.cvcn.gov.it/cvcn/cve/CVE-2025-3499\",\"source\":\"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-3499\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-09T13:06:55.487400Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-09T13:07:54.556Z\"}}], \"cna\": {\"title\": \"Unauthenticated execution of arbitrary commands in Radiflow iSAP Smart Collector\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 10, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Radiflow\", \"product\": \"iSAP Smart Collector\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.20\", \"lessThan\": \"3.02-1\", \"versionType\": \"semver\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.cvcn.gov.it/cvcn/cve/CVE-2025-3499\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The device has two web servers that expose unauthenticated REST APIs on the management network (TCP\\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\\ncommands that are executed with administrative permissions by the underlying operating system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\nThe device has two web servers that expose unauthenticated REST APIs on the management network (TCP\\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\\ncommands that are executed with administrative permissions by the underlying operating system.\u003cbr\u003e\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\\u2019OS Command Injection\\u2019)\"}]}], \"providerMetadata\": {\"orgId\": \"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158\", \"shortName\": \"ENISA\", \"dateUpdated\": \"2025-07-09T08:57:26.893Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-3499\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-09T13:08:05.257Z\", \"dateReserved\": \"2025-04-10T08:40:15.892Z\", \"assignerOrgId\": \"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158\", \"datePublished\": \"2025-07-09T08:57:26.893Z\", \"assignerShortName\": \"ENISA\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…