CVE-2025-40570 (GCVE-0-2025-40570)

Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-12 20:08
VLAI?
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
Impacted products
Vendor Product Version
Siemens SIPROTEC 5 6MD84 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 6MD85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 6MD86 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 6MD89 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 6MU85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7KE85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SA82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SA86 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SA87 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SD82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SD86 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SD87 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SJ81 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SJ82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SJ85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SJ86 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SK82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SK85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SL82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SL86 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SL87 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SS85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7ST85 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7ST86 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SX82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SX85 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7SY82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7UM85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7UT82 (CP150) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7UT85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7UT86 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7UT87 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7VE85 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7VK87 (CP300) Affected: V7.80 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 7VU85 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
    Siemens SIPROTEC 5 Compact 7SX800 (CP050) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40570",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T20:08:07.253344Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T20:08:15.284Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD84 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD89 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SY82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UM85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Compact 7SX800 (CP050)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V10.0), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:01.195Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-894058.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40570",
    "datePublished": "2025-08-12T11:17:01.195Z",
    "dateReserved": "2025-04-16T08:20:17.031Z",
    "dateUpdated": "2025-08-12T20:08:15.284Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-40570\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-08-12T12:15:35.387\",\"lastModified\":\"2025-08-12T14:25:33.177\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V10.0), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 6MD85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 6MD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 6MD89 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 6MU85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7KE85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SA82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SA86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SA87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SD82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SD87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SK82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SK85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SL82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SL86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SL87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7SS85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7ST85 (CP300) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7ST86 (CP300) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SX82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SX85 (CP300) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7SY82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7UM85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7UT82 (CP150) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 7UT85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7UT86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7UT87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7VE85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7VK87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V10.0), SIPROTEC 5 7VU85 (CP300) (Todas las versiones \u0026lt; V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (Todas las versiones \u0026lt; V10.0). Los dispositivos afectados no limitan correctamente el ancho de banda para los paquetes de red entrantes a trav\u00e9s de su puerto USB local. Esto podr\u00eda permitir que un atacante con acceso f\u00edsico env\u00ede paquetes especialmente manipulados con un alto ancho de banda a los dispositivos afectados, oblig\u00e1ndolos a agotar su memoria y a dejar de responder al tr\u00e1fico de red a trav\u00e9s del puerto USB local. Los dispositivos afectados se reinician autom\u00e1ticamente tras un ataque exitoso. La funci\u00f3n de protecci\u00f3n no se ve afectada por esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":2.4,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":2.4,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-894058.html\",\"source\":\"productcert@siemens.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-08-12T11:17:01.195Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V10.0), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.\"}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD84 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD89 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MU85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7KE85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ81 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SK82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SK85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SS85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7ST85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7ST86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SX82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SX85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SY82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UM85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7VE85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7VK87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7VU85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 Compact 7SX800 (CP050)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 2.4, \"baseSeverity\": \"LOW\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N\", \"baseScore\": 2.4, \"baseSeverity\": \"LOW\"}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"cweId\": \"CWE-770\", \"description\": \"CWE-770: Allocation of Resources Without Limits or Throttling\", \"type\": \"CWE\"}]}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-894058.html\"}]}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-40570\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-12T20:08:07.253344Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-12T20:08:11.293Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-40570\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"siemens\", \"dateReserved\": \"2025-04-16T08:20:17.031Z\", \"datePublished\": \"2025-08-12T11:17:01.195Z\", \"dateUpdated\": \"2025-08-12T20:08:15.284Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…