CVE-2025-52586 (GCVE-0-2025-52586)

Vulnerability from cvelistv5 – Published: 2025-08-08 16:00 – Updated: 2025-09-08 17:06
VLAI?
Summary
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
CWE
Assigner
Credits
Anthony Rose of BC Security reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-52586",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-08T16:12:13.892869Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-08T16:12:28.064Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EG4 12kPV",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EG4 18kPV",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EG4 Flex 21",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EG4 Flex 18",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EG4 6000XP",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EG4 12000XP",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EG4 GridBoss",
          "vendor": "EG4 Electronics",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Anthony Rose of BC Security reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The MOD3 command traffic between the monitoring application and the \ninverter is transmitted in plaintext without encryption or obfuscation. \nThis vulnerability may allow an attacker with access to a local network \nto intercept, manipulate, replay, or forge critical data, including \nread/write operations for voltage, current, and power configuration, \noperational status, alarms, telemetry, system reset, or inverter control\n commands, potentially disrupting power generation or reconfiguring \ninverter settings."
            }
          ],
          "value": "The MOD3 command traffic between the monitoring application and the \ninverter is transmitted in plaintext without encryption or obfuscation. \nThis vulnerability may allow an attacker with access to a local network \nto intercept, manipulate, replay, or forge critical data, including \nread/write operations for voltage, current, and power configuration, \noperational status, alarms, telemetry, system reset, or inverter control\n commands, potentially disrupting power generation or reconfiguring \ninverter settings."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-08T17:06:06.953Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-07"
        },
        {
          "url": "https://eg4electronics.com/contact/"
        },
        {
          "url": "https://eg4electronics.com/wp-content/uploads/2025/09/EG4-Wi-Fi-Dongle-Dongle-Firmware-Update.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-25-219-07",
        "discovery": "EXTERNAL"
      },
      "title": "EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eEG4 has acknowledged the vulnerabilities and is actively working on a\n fix, including new hardware expected to release by October 15, 2025. \nUntil then, EG4 will actively monitor all installed systems and work \nwith affected users on a case-by-case basis if anomalies are observed.\u003cbr\u003e\u003c/p\u003e\n\n\u003cp\u003eFor more information, \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://eg4electronics.com/contact/\"\u003econtact EG4.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "EG4 has acknowledged the vulnerabilities and is actively working on a\n fix, including new hardware expected to release by October 15, 2025. \nUntil then, EG4 will actively monitor all installed systems and work \nwith affected users on a case-by-case basis if anomalies are observed.\n\n\n\n\nFor more information,  contact EG4. https://eg4electronics.com/contact/"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-52586",
    "datePublished": "2025-08-08T16:00:43.694Z",
    "dateReserved": "2025-07-30T19:03:10.056Z",
    "dateUpdated": "2025-09-08T17:06:06.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-52586\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-08-08T16:15:27.617\",\"lastModified\":\"2025-09-08T17:15:34.037\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The MOD3 command traffic between the monitoring application and the \\ninverter is transmitted in plaintext without encryption or obfuscation. \\nThis vulnerability may allow an attacker with access to a local network \\nto intercept, manipulate, replay, or forge critical data, including \\nread/write operations for voltage, current, and power configuration, \\noperational status, alarms, telemetry, system reset, or inverter control\\n commands, potentially disrupting power generation or reconfiguring \\ninverter settings.\"},{\"lang\":\"es\",\"value\":\"El tr\u00e1fico de comandos MOD3 entre la aplicaci\u00f3n de monitorizaci\u00f3n y el inversor se transmite en texto plano, sin cifrado ni ofuscaci\u00f3n. Esta vulnerabilidad podr\u00eda permitir que un atacante con acceso a una red local intercepte, manipule, reproduzca o falsifique datos cr\u00edticos, como operaciones de lectura/escritura de voltaje, corriente y configuraci\u00f3n de potencia, estado operativo, alarmas, telemetr\u00eda, reinicio del sistema o comandos de control del inversor, lo que podr\u00eda interrumpir la generaci\u00f3n de energ\u00eda o reconfigurar los ajustes del inversor.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L\",\"baseScore\":6.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.4,\"impactScore\":5.5}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"references\":[{\"url\":\"https://eg4electronics.com/contact/\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://eg4electronics.com/wp-content/uploads/2025/09/EG4-Wi-Fi-Dongle-Dongle-Firmware-Update.pdf\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-07\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-52586\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-08T16:12:13.892869Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-08T16:12:20.324Z\"}}], \"cna\": {\"title\": \"EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information\", \"source\": {\"advisory\": \"ICSA-25-219-07\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Anthony Rose of BC Security reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.9, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 12kPV\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 18kPV\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 Flex 21\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 Flex 18\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 6000XP\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 12000XP\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"EG4 Electronics\", \"product\": \"EG4 GridBoss\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-07\"}, {\"url\": \"https://eg4electronics.com/contact/\"}, {\"url\": \"https://eg4electronics.com/wp-content/uploads/2025/09/EG4-Wi-Fi-Dongle-Dongle-Firmware-Update.pdf\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"EG4 has acknowledged the vulnerabilities and is actively working on a\\n fix, including new hardware expected to release by October 15, 2025. \\nUntil then, EG4 will actively monitor all installed systems and work \\nwith affected users on a case-by-case basis if anomalies are observed.\\n\\n\\n\\n\\nFor more information,  contact EG4. https://eg4electronics.com/contact/\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eEG4 has acknowledged the vulnerabilities and is actively working on a\\n fix, including new hardware expected to release by October 15, 2025. \\nUntil then, EG4 will actively monitor all installed systems and work \\nwith affected users on a case-by-case basis if anomalies are observed.\u003cbr\u003e\u003c/p\u003e\\n\\n\u003cp\u003eFor more information, \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://eg4electronics.com/contact/\\\"\u003econtact EG4.\u003c/a\u003e\u003c/p\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The MOD3 command traffic between the monitoring application and the \\ninverter is transmitted in plaintext without encryption or obfuscation. \\nThis vulnerability may allow an attacker with access to a local network \\nto intercept, manipulate, replay, or forge critical data, including \\nread/write operations for voltage, current, and power configuration, \\noperational status, alarms, telemetry, system reset, or inverter control\\n commands, potentially disrupting power generation or reconfiguring \\ninverter settings.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The MOD3 command traffic between the monitoring application and the \\ninverter is transmitted in plaintext without encryption or obfuscation. \\nThis vulnerability may allow an attacker with access to a local network \\nto intercept, manipulate, replay, or forge critical data, including \\nread/write operations for voltage, current, and power configuration, \\noperational status, alarms, telemetry, system reset, or inverter control\\n commands, potentially disrupting power generation or reconfiguring \\ninverter settings.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-319\", \"description\": \"CWE-319\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-09-08T17:06:06.953Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-52586\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-08T17:06:06.953Z\", \"dateReserved\": \"2025-07-30T19:03:10.056Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-08-08T16:00:43.694Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…