CVE-2025-56498 (GCVE-0-2025-56498)

Vulnerability from cvelistv5 – Published: 2025-09-03 00:00 – Updated: 2025-09-03 20:03
VLAI?
Summary
An OS command injection vulnerability exists in PLDT WiFi Router's Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-56498",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-03T20:01:33.019752Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-03T20:03:01.578Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An OS command injection vulnerability exists in PLDT WiFi Router\u0027s Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-03T15:37:09.981Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://prolink2u.com/products/pgn6401v"
        },
        {
          "url": "https://github.com/Jorge2Rubio/CVEs/blob/main/CVE-2025-56498.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-56498",
    "datePublished": "2025-09-03T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-09-03T20:03:01.578Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-56498\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2025-09-03T16:15:40.193\",\"lastModified\":\"2025-09-09T15:58:46.043\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An OS command injection vulnerability exists in PLDT WiFi Router\u0027s Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:prolink2u:pgn6401v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.1.2\",\"matchCriteriaId\":\"49A20746-3F84-4D44-8947-3E2CA43E0BCA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:prolink2u:pgn6401v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E1580878-C7D7-47AC-BFA3-2B90035F38D4\"}]}]}],\"references\":[{\"url\":\"https://github.com/Jorge2Rubio/CVEs/blob/main/CVE-2025-56498.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://prolink2u.com/products/pgn6401v\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-56498\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-03T20:01:33.019752Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-03T20:02:56.480Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://prolink2u.com/products/pgn6401v\"}, {\"url\": \"https://github.com/Jorge2Rubio/CVEs/blob/main/CVE-2025-56498.md\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An OS command injection vulnerability exists in PLDT WiFi Router\u0027s Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-09-03T15:37:09.981Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-56498\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-03T20:03:01.578Z\", \"dateReserved\": \"2025-08-17T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2025-09-03T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…