CVE-2025-8703 (GCVE-0-2025-8703)
Vulnerability from cvelistv5 – Published: 2025-08-08 00:02 – Updated: 2025-08-08 17:14
VLAI?
Title
Wanzhou WOES Intelligent Optimization Energy Saving System Environmental Real-Time Data Module GetAreaTrendChartData sql injection
Summary
A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Wanzhou | WOES Intelligent Optimization Energy Saving System |
Affected:
1.0
|
Credits
cgs1234 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8703",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-08T17:13:15.704240Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-08T17:14:03.198Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Environmental Real-Time Data Module"
],
"product": "WOES Intelligent Optimization Energy Saving System",
"vendor": "Wanzhou",
"versions": [
{
"status": "affected",
"version": "1.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "cgs1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Wanzhou WOES Intelligent Optimization Energy Saving System 1.0 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist eine unbekannte Verarbeitung der Datei /WEAS_HomePage/GetAreaTrendChartData der Komponente Environmental Real-Time Data Module. Dank der Manipulation des Arguments energyId mit unbekannten Daten kann eine sql injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "SQL Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-08T00:02:06.332Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-319132 | Wanzhou WOES Intelligent Optimization Energy Saving System Environmental Real-Time Data Module GetAreaTrendChartData sql injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.319132"
},
{
"name": "VDB-319132 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.319132"
},
{
"name": "Submit #621278 | Worldwide Electric Stock Co.,Ltd. WOES Intelligent Optimization Energy saving System V1.0 SQL Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.621278"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/si12/xxx/issues/3"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-08-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-08-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-08-07T16:13:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Wanzhou WOES Intelligent Optimization Energy Saving System Environmental Real-Time Data Module GetAreaTrendChartData sql injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-8703",
"datePublished": "2025-08-08T00:02:06.332Z",
"dateReserved": "2025-08-07T14:08:41.433Z",
"dateUpdated": "2025-08-08T17:14:03.198Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-8703\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-08-08T01:15:25.463\",\"lastModified\":\"2025-09-03T15:29:49.920\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 una vulnerabilidad cr\u00edtica en Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. Esta vulnerabilidad afecta al c\u00f3digo desconocido del archivo /WEAS_HomePage/GetAreaTrendChartData del componente Environmental Real-Time Data Module. La manipulaci\u00f3n del argumento energyId provoca una inyecci\u00f3n SQL. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"},{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:wanzhou:woes_intelligent_optimization_energy_saving_system:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"249090F6-5928-4E3A-9251-53BB16F4073E\"}]}]}],\"references\":[{\"url\":\"https://github.com/si12/xxx/issues/3\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Issue Tracking\"]},{\"url\":\"https://vuldb.com/?ctiid.319132\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.319132\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.621278\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-8703\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-08T17:13:15.704240Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-08T17:13:55.882Z\"}}], \"cna\": {\"title\": \"Wanzhou WOES Intelligent Optimization Energy Saving System Environmental Real-Time Data Module GetAreaTrendChartData sql injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"cgs1234 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"Wanzhou\", \"modules\": [\"Environmental Real-Time Data Module\"], \"product\": \"WOES Intelligent Optimization Energy Saving System\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-08-07T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-08-07T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-08-07T16:13:59.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.319132\", \"name\": \"VDB-319132 | Wanzhou WOES Intelligent Optimization Energy Saving System Environmental Real-Time Data Module GetAreaTrendChartData sql injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.319132\", \"name\": \"VDB-319132 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.621278\", \"name\": \"Submit #621278 | Worldwide Electric Stock Co.,Ltd. WOES Intelligent Optimization Energy saving System V1.0 SQL Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/si12/xxx/issues/3\", \"tags\": [\"exploit\", \"issue-tracking\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.\"}, {\"lang\": \"de\", \"value\": \"In Wanzhou WOES Intelligent Optimization Energy Saving System 1.0 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist eine unbekannte Verarbeitung der Datei /WEAS_HomePage/GetAreaTrendChartData der Komponente Environmental Real-Time Data Module. Dank der Manipulation des Arguments energyId mit unbekannten Daten kann eine sql injection-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk passieren. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"SQL Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-74\", \"description\": \"Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-08-08T00:02:06.332Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-8703\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-08T17:14:03.198Z\", \"dateReserved\": \"2025-08-07T14:08:41.433Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-08-08T00:02:06.332Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…