CVE-2026-21223 (GCVE-0-2026-21223)

Vulnerability from cvelistv5 – Published: 2026-01-16 21:28 – Updated: 2026-01-16 21:50
VLAI?
Title
Microsoft Edge (Chromium-based) Security Feature Bypass Vulnerability
Summary
Microsoft Edge Elevation Service exposes a privileged COM interface that inadequately validates the privileges of the calling process. A standard (non‑administrator) local user can invoke the IElevatorEdge interface method LaunchUpdateCmdElevatedAndWait, causing the service to execute privileged update commands as LocalSystem. This allows a non‑administrator to enable or disable Windows Virtualization‑Based Security (VBS) by modifying protected system registry keys under HKLM\SYSTEM\CurrentControlSet\Control\DeviceGuard. Disabling VBS weakens critical platform protections such as Credential Guard, Hypervisor‑protected Code Integrity (HVCI), and the Secure Kernel, resulting in a security feature bypass.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
Microsoft Microsoft Edge (Chromium-based) Affected: 1.0.0.0 , < 144.0.3719.82 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2026-21223",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-16T21:49:58.994370Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-16T21:50:24.474Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Microsoft Edge (Chromium-based)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "144.0.3719.82",
              "status": "affected",
              "version": "1.0.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:edge_chromium:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "144.0.3719.82",
                  "versionStartIncluding": "1.0.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2026-01-16T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Microsoft Edge Elevation Service exposes a privileged COM interface that inadequately validates the privileges of the calling process. A standard (non\u2011administrator) local user can invoke the IElevatorEdge interface method LaunchUpdateCmdElevatedAndWait, causing the service to execute privileged update commands as LocalSystem.\nThis allows a non\u2011administrator to enable or disable Windows Virtualization\u2011Based Security (VBS) by modifying protected system registry keys under HKLM\\SYSTEM\\CurrentControlSet\\Control\\DeviceGuard. Disabling VBS weakens critical platform protections such as Credential Guard, Hypervisor\u2011protected Code Integrity (HVCI), and the Secure Kernel, resulting in a security feature bypass."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-16T21:28:30.158Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Microsoft Edge (Chromium-based) Security Feature Bypass Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-21223"
        }
      ],
      "title": "Microsoft Edge (Chromium-based) Security Feature Bypass Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2026-21223",
    "datePublished": "2026-01-16T21:28:30.158Z",
    "dateReserved": "2025-12-11T21:02:05.732Z",
    "dateUpdated": "2026-01-16T21:50:24.474Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-21223\",\"sourceIdentifier\":\"secure@microsoft.com\",\"published\":\"2026-01-16T22:16:25.983\",\"lastModified\":\"2026-01-16T22:16:25.983\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Microsoft Edge Elevation Service exposes a privileged COM interface that inadequately validates the privileges of the calling process. A standard (non\u2011administrator) local user can invoke the IElevatorEdge interface method LaunchUpdateCmdElevatedAndWait, causing the service to execute privileged update commands as LocalSystem.\\nThis allows a non\u2011administrator to enable or disable Windows Virtualization\u2011Based Security (VBS) by modifying protected system registry keys under HKLM\\\\SYSTEM\\\\CurrentControlSet\\\\Control\\\\DeviceGuard. Disabling VBS weakens critical platform protections such as Credential Guard, Hypervisor\u2011protected Code Integrity (HVCI), and the Secure Kernel, resulting in a security feature bypass.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\",\"baseScore\":5.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.5,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"secure@microsoft.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"references\":[{\"url\":\"https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-21223\",\"source\":\"secure@microsoft.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.1, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-21223\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-16T21:49:58.994370Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-16T21:50:19.043Z\"}}], \"cna\": {\"title\": \"Microsoft Edge (Chromium-based) Security Feature Bypass Vulnerability\", \"affected\": [{\"vendor\": \"Microsoft\", \"product\": \"Microsoft Edge (Chromium-based)\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.0.0\", \"lessThan\": \"144.0.3719.82\", \"versionType\": \"custom\"}]}], \"datePublic\": \"2026-01-16T08:00:00.000Z\", \"references\": [{\"url\": \"https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-21223\", \"name\": \"Microsoft Edge (Chromium-based) Security Feature Bypass Vulnerability\", \"tags\": [\"vendor-advisory\", \"patch\"]}], \"descriptions\": [{\"lang\": \"en-US\", \"value\": \"Microsoft Edge Elevation Service exposes a privileged COM interface that inadequately validates the privileges of the calling process. A standard (non\\u2011administrator) local user can invoke the IElevatorEdge interface method LaunchUpdateCmdElevatedAndWait, causing the service to execute privileged update commands as LocalSystem.\\nThis allows a non\\u2011administrator to enable or disable Windows Virtualization\\u2011Based Security (VBS) by modifying protected system registry keys under HKLM\\\\SYSTEM\\\\CurrentControlSet\\\\Control\\\\DeviceGuard. Disabling VBS weakens critical platform protections such as Credential Guard, Hypervisor\\u2011protected Code Integrity (HVCI), and the Secure Kernel, resulting in a security feature bypass.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en-US\", \"type\": \"CWE\", \"cweId\": \"CWE-269\", \"description\": \"CWE-269: Improper Privilege Management\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:microsoft:edge_chromium:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"144.0.3719.82\", \"versionStartIncluding\": \"1.0.0.0\"}], \"operator\": \"OR\"}]}], \"providerMetadata\": {\"orgId\": \"f38d906d-7342-40ea-92c1-6c4a2c6478c8\", \"shortName\": \"microsoft\", \"dateUpdated\": \"2026-01-16T21:28:30.158Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-21223\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-16T21:50:24.474Z\", \"dateReserved\": \"2025-12-11T21:02:05.732Z\", \"assignerOrgId\": \"f38d906d-7342-40ea-92c1-6c4a2c6478c8\", \"datePublished\": \"2026-01-16T21:28:30.158Z\", \"assignerShortName\": \"microsoft\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…