CVE-2026-5397 (GCVE-0-2026-5397)
Vulnerability from cvelistv5 – Published: 2026-04-15 04:11 – Updated: 2026-04-15 16:13
VLAI
Title
Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application
Summary
It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.
If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| OMRON SOCIAL SOLUTIONS CO., Ltd. | PowerAttendant Standard Edition |
Affected:
2.1.2 or lower
(custom)
|
Date Public
2026-04-15 04:08
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-15T13:46:38.260570Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T16:13:26.313Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "PowerAttendant Standard Edition",
"vendor": "OMRON SOCIAL SOLUTIONS CO., Ltd.",
"versions": [
{
"status": "affected",
"version": "2.1.2 or lower",
"versionType": "custom"
}
]
}
],
"datePublic": "2026-04-15T04:08:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eIt has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u0026nbsp;is then executed with administrator privileges.\u003c/div\u003eIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u0026nbsp;may be executed by exploiting the product\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup."
}
],
"value": "It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u00a0is then executed with administrator privileges.\n\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u00a0may be executed by exploiting the product\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup."
}
],
"impacts": [
{
"capecId": "CAPEC-471",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-471 Search Order Hijacking"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T04:11:29.716Z",
"orgId": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
"shortName": "OMRON"
},
"references": [
{
"url": "https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf"
},
{
"url": "https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application",
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
"assignerShortName": "OMRON",
"cveId": "CVE-2026-5397",
"datePublished": "2026-04-15T04:11:29.716Z",
"dateReserved": "2026-04-02T00:17:38.524Z",
"dateUpdated": "2026-04-15T16:13:26.313Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-5397",
"date": "2026-06-02",
"epss": "0.00014",
"percentile": "0.02595"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-5397\",\"sourceIdentifier\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\",\"published\":\"2026-04-15T05:16:45.740\",\"lastModified\":\"2026-04-17T15:17:00.957\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u00a0is then executed with administrator privileges.\\n\\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u00a0may be executed by exploiting the product\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.1,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"references\":[{\"url\":\"https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf\",\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\"},{\"url\":\"https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf\",\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-5397\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-15T13:46:38.260570Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-15T13:46:44.852Z\"}}], \"cna\": {\"title\": \"Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-471\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-471 Search Order Hijacking\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"OMRON SOCIAL SOLUTIONS CO., Ltd.\", \"product\": \"PowerAttendant Standard Edition\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.1.2 or lower\", \"versionType\": \"custom\"}], \"platforms\": [\"Windows\"], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-04-15T04:08:00.000Z\", \"references\": [{\"url\": \"https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf\"}, {\"url\": \"https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\\u00a0is then executed with administrator privileges.\\n\\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\\u00a0may be executed by exploiting the product\\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003eIt has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u0026nbsp;is then executed with administrator privileges.\u003c/div\u003eIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u0026nbsp;may be executed by exploiting the product\\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-427\", \"description\": \"CWE-427 Uncontrolled Search Path Element\"}]}], \"providerMetadata\": {\"orgId\": \"bba440f9-ef23-4224-aa62-7ac0935d18d1\", \"shortName\": \"OMRON\", \"dateUpdated\": \"2026-04-15T04:11:29.716Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-5397\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-15T16:13:26.313Z\", \"dateReserved\": \"2026-04-02T00:17:38.524Z\", \"assignerOrgId\": \"bba440f9-ef23-4224-aa62-7ac0935d18d1\", \"datePublished\": \"2026-04-15T04:11:29.716Z\", \"assignerShortName\": \"OMRON\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…