FKIE_CVE-2014-9197
Vulnerability from fkie_nvd - Published: 2015-01-27 19:59 - Updated: 2025-09-05 22:15
Severity ?
Summary
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | etg3000_factorycast_hmi_gateway_firmware | 1.60.2 | |
| schneider-electric | tsxetg3000 | - | |
| schneider-electric | tsxetg3010 | - | |
| schneider-electric | tsxetg3021 | - | |
| schneider-electric | tsxetg3022 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:etg3000_factorycast_hmi_gateway_firmware:1.60.2:*:*:*:*:*:*:*",
"matchCriteriaId": "88278ADF-FD66-4110-80F2-059D98B5D740",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tsxetg3000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "46D2618A-486E-4055-BAFD-81F82C6B3D2A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:schneider-electric:tsxetg3010:-:*:*:*:*:*:*:*",
"matchCriteriaId": "55B765EF-1FA4-4994-AE8C-E11BF4F9B95E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:schneider-electric:tsxetg3021:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB5F2A27-898A-4F8F-BAD5-FA64370A6B98",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:schneider-electric:tsxetg3022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2D483984-53F3-4972-9F6D-9446C06891D5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
},
{
"lang": "es",
"value": "Schneider Electric ETG3000 FactoryCast HMI Gateway con firmware anterior a 1.60 IR 04 almacena rde.jar bajo el root web sin suficiente control de acceso, lo que permite a atacantes remotos obtener informaci\u00f3n sensible de la instalaci\u00f3n y la configuraci\u00f3n a trav\u00e9s de una solicitud directa."
}
],
"id": "CVE-2014-9197",
"lastModified": "2025-09-05T22:15:33.210",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": false
},
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2015-01-27T19:59:00.040",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-020-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…