FKIE_CVE-2017-7970
Vulnerability from fkie_nvd - Published: 2017-09-26 01:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/ | Mitigation, Patch, Vendor Advisory | |
| cybersecurity@se.com | http://www.securityfocus.com/bid/99913 | Third Party Advisory, VDB Entry | |
| cybersecurity@se.com | https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere | Issue Tracking, Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/ | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/99913 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere | Issue Tracking, Mitigation, Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | powerscada_anywhere | 1.0 | |
| schneider-electric | powerscada_expert | 8.1 | |
| schneider-electric | powerscada_expert | 8.2 | |
| schneider-electric | citect_anywhere | 1.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6445511E-70B8-4E03-A178-FFDBE02E1609",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*",
"matchCriteriaId": "AE171A71-B1AF-471B-9D27-07D4491D05B3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*",
"matchCriteriaId": "D2A3FA74-D201-41AA-BDA1-82816813AD11",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5182F21D-1DF5-492A-9A3D-B913AC6B12F6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en la versi\u00f3n 1.0 de PowerSCADA Anywhere de Schneider Electric redistribuida con PowerSCADA Expert 8.1, PowerSCADA Expert 8.2 y Citect Anywhere 1.0 que permite que se especifiquen nodos de destino del servidor arbitrarios en peticiones de conexi\u00f3n a los componentes de Secure Gateway y Server."
}
],
"id": "CVE-2017-7970",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-09-26T01:29:03.537",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99913"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Issue Tracking",
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99913"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Issue Tracking",
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…