FKIE_CVE-2018-7831
Vulnerability from fkie_nvd - Published: 2018-11-30 19:29 - Updated: 2024-11-21 04:12
Severity ?
Summary
An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on the web server.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/ | Vendor Advisory | |
| cybersecurity@se.com | https://www.tenable.com/security/research/tra-2018-38 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2018-38 | Exploit, Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicom_m340_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A53C0B78-6556-44B7-9546-75F48EDD87CB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicom_m340:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7F3D3249-CD51-496E-AB39-79D53EB318F8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicom_premium_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA79EF8E-C525-4CCB-AC21-F7493FA55BF7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicom_premium:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F3ED1E3-2D3F-4ACD-84C9-FD282C4845D9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicom_quantum_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62BAE494-82C9-4CC7-8149-37DD1ADA10F2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicom_quantum:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC2867F0-53B1-465E-A413-6EFE4ED0FFC4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicom_bmxnor0200h_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D99FE33D-BBA0-40B7-B79C-E276BF8353FB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicom_bmxnor0200h:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C420C7F-5B35-4775-8775-241FDD0B759C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on the web server."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de neutralizaci\u00f3n incorrecta de etiquetas HTML relacionadas con scripts en una p\u00e1gina web (XSS b\u00e1sico) en los servidores web embebidos en todos los productos Modicon M340, Premium, Quantum PLCs y BMXNOR0200, lo que podr\u00eda permitir que un atacante env\u00ede una URL especialmente manipulada a un usuario autenticado del servidor web para que ejecute un cambio de contrase\u00f1a en el servidor web."
}
],
"id": "CVE-2018-7831",
"lastModified": "2024-11-21T04:12:50.497",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-11-30T19:29:00.593",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2018-38"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2018-38"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
},
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…