FKIE_CVE-2019-12702
Vulnerability from fkie_nvd - Published: 2019-10-16 19:15 - Updated: 2024-11-21 04:23
Severity ?
Summary
A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| cisco | spa112_firmware | * | |
| cisco | spa112_firmware | 1.4.1 | |
| cisco | spa112_firmware | 1.4.1 | |
| cisco | spa112_firmware | 1.4.1 | |
| cisco | spa112_firmware | 1.4.1 | |
| cisco | spa112 | - | |
| cisco | spa122_firmware | * | |
| cisco | spa122_firmware | 1.4.1 | |
| cisco | spa122_firmware | 1.4.1 | |
| cisco | spa122_firmware | 1.4.1 | |
| cisco | spa122_firmware | 1.4.1 | |
| cisco | spa122 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:spa112_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CDE978DB-5C48-4E25-A67E-497F033366E1",
"versionEndExcluding": "1.4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:-:*:*:*:*:*:*",
"matchCriteriaId": "CDBCF90E-2E7B-4A58-B0DF-4A02D880EF0D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr1:*:*:*:*:*:*",
"matchCriteriaId": "661CECD1-038C-41B1-AEB7-9C3E5087E088",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr2:*:*:*:*:*:*",
"matchCriteriaId": "691B5688-DDAF-49EE-8E9F-ABB06BB628B0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr3:*:*:*:*:*:*",
"matchCriteriaId": "C4BAC9C2-3475-42EC-81FA-12BE338C936A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:spa112:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F61B8649-0781-4AF5-8CED-34616A9524FF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:spa122_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "22E490C8-BA3D-44E0-A677-C3311489EED5",
"versionEndExcluding": "1.4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:-:*:*:*:*:*:*",
"matchCriteriaId": "30A5E568-2B2A-4A46-99E9-5FC203F96347",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr1:*:*:*:*:*:*",
"matchCriteriaId": "4A1FCBBE-9EE3-4D9D-AD25-2D4FA5893263",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr2:*:*:*:*:*:*",
"matchCriteriaId": "6D77D805-40B9-41F1-9A1A-C1A85E89361E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr3:*:*:*:*:*:*",
"matchCriteriaId": "1B7D0675-063B-45A2-985D-B32FF3D6E15B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:spa122:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C874C71-46D9-48A4-81C9-7ADDDB22FC8C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web de los dispositivos Cisco SPA100 Series Analog Telephone Adapters (ATAs), podr\u00eda permitir a un atacante remoto autenticado conducir ataques de tipo cross-site scripting. La vulnerabilidad es debido a una comprobaci\u00f3n insuficiente de la entrada suministrada por el usuario mediante la interfaz de administraci\u00f3n basada en web del software afectado. Un atacante podr\u00eda explotar esta vulnerabilidad persuadiendo a un usuario para que haga clic en un enlace dise\u00f1ado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo de script arbitrario en el contexto de la interfaz afectada o acceder a informaci\u00f3n confidencial basada en navegador."
}
],
"id": "CVE-2019-12702",
"lastModified": "2024-11-21T04:23:23.773",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "psirt@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-10-16T19:15:11.427",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…