FKIE_CVE-2019-15995
Vulnerability from fkie_nvd - Published: 2019-11-26 04:15 - Updated: 2024-11-21 04:29
Severity ?
Summary
A vulnerability in the web UI of Cisco DNA Spaces: Connector could allow an authenticated, remote attacker to execute arbitrary SQL queries. The vulnerability exists because the web UI does not properly validate user-supplied input. An attacker could exploit this vulnerability by entering malicious SQL statements in an affected field in the web UI. A successful exploit could allow the attacker to remove the SQL database, which would require the reinstallation of the Connector VM.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| cisco | dna_spaces\ | _connector |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:dna_spaces\\:_connector:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51D3CA9D-FB9D-401A-A593-BCAEE1210BEC",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web UI of Cisco DNA Spaces: Connector could allow an authenticated, remote attacker to execute arbitrary SQL queries. The vulnerability exists because the web UI does not properly validate user-supplied input. An attacker could exploit this vulnerability by entering malicious SQL statements in an affected field in the web UI. A successful exploit could allow the attacker to remove the SQL database, which would require the reinstallation of the Connector VM."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la Interfaz de Usuario web de Cisco DNA Spaces: Connector, podr\u00eda permitir a un atacante remoto autenticado ejecutar consultas SQL arbitrarias. La vulnerabilidad se presenta porque la interfaz de usuario web no comprueba correctamente la entrada suministrada por el usuario. Un atacante podr\u00eda explotar esta vulnerabilidad al ingresar sentencias SQL maliciosas en un campo afectado en la Interfaz de Usuario web. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante suprimir la base de datos SQL, lo que requerir\u00eda la reinstalaci\u00f3n de la VM de Connector."
}
],
"id": "CVE-2019-15995",
"lastModified": "2024-11-21T04:29:53.730",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.2,
"source": "psirt@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-11-26T04:15:12.247",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191120-dna-sqlinjection"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191120-dna-sqlinjection"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…