FKIE_CVE-2019-6830

Vulnerability from fkie_nvd - Published: 2019-09-17 20:15 - Updated: 2026-06-17 02:39
Summary
A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller.
Impacted products

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Modicon M580",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "all versions prior to V2.80"
            }
          ]
        }
      ],
      "source": "cybersecurity@se.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDEB227-D50B-402C-9C11-E29F52BC10BB",
              "versionEndExcluding": "2.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E876C738-ABF6-4864-98A6-1E06E96A0DF4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller."
    },
    {
      "lang": "es",
      "value": "Una CWE-248: Se presenta una vulnerabilidad Excepci\u00f3n No Capturada en Modicon M580 todas las versiones anteriores a V2.80, lo que podr\u00eda causar una posible denegaci\u00f3n de servicio cuando se env\u00eda una petici\u00f3n HTTP  temporizada de manera apropiada al controlador."
    }
  ],
  "id": "CVE-2019-6830",
  "lastModified": "2026-06-17T02:39:45.423",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-09-17T20:15:12.267",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-248"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-755"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…