FKIE_CVE-2020-12028
Vulnerability from fkie_nvd - Published: 2020-07-20 16:15 - Updated: 2024-11-21 04:59
Severity ?
7.3 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Summary
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html | Exploit, Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944 | Vendor Advisory | |
| ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| rockwellautomation | factorytalk_view | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*",
"matchCriteriaId": "4DDF668E-9D30-4588-8897-474014D746A5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs."
},
{
"lang": "es",
"value": "En todas las versiones de FactoryTalk View SEA un atacante autenticado remoto puede ser capaz de usar determinados manejadores para interactuar con los datos en el endpoint remoto, ya que esos controladores no aplican los permisos apropiados. Rockwell Automation recomienda habilitar las funciones de seguridad integradas que se encuentran en FactoryTalk View SE. Los usuarios deben seguir la gu\u00eda que se encuentra en los art\u00edculos 109056 y 1126943 de la base de conocimiento para configurar IPSec y/o HTTP"
}
],
"id": "CVE-2020-12028",
"lastModified": "2024-11-21T04:59:08.567",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.2,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-20T16:15:12.163",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-264"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…