FKIE_CVE-2020-5725

Vulnerability from fkie_nvd - Published: 2020-03-30 20:15 - Updated: 2024-11-21 05:34
Summary
The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server's websockify endpoint. A remote unauthenticated attacker can invoke the login action with a crafted username and, through the use of timing attacks, can discover user passwords.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F55C1906-9C0D-4479-B545-059329485BCD",
              "versionEndExcluding": "1.0.20.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:grandstream:ucm6202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9864BD0F-BE9C-4F72-AB57-77036699029B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D9A2414-684F-4C61-BCAC-E7967A7BFF2B",
              "versionEndExcluding": "1.0.20.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:grandstream:ucm6204:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5A26ABB-8BED-4E61-91AA-ABF1B90CBD81",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3164240C-6CAB-4433-8EB3-5F09552A7F4D",
              "versionEndExcluding": "1.0.20.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:grandstream:ucm6208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA744718-8862-4579-B9CF-E1E8137A02E6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server\u0027s websockify endpoint. A remote unauthenticated attacker can invoke the login action with a crafted username and, through the use of timing attacks, can discover user passwords."
    },
    {
      "lang": "es",
      "value": "La serie Grandstream UCM6200 versiones anteriores a 1.0.20.22, es vulnerable a una inyecci\u00f3n SQL por medio del endpoint websockify del servidor HTTP. Un atacante no autenticado remoto puede invocar la acci\u00f3n login con un nombre de usuario dise\u00f1ado y, mediante el uso de ataques de tiempo, puede detectar contrase\u00f1as de usuario."
    }
  ],
  "id": "CVE-2020-5725",
  "lastModified": "2024-11-21T05:34:29.400",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-03-30T20:15:20.133",
  "references": [
    {
      "source": "vulnreport@tenable.com",
      "url": "http://packetstormsecurity.com/files/156976/Grandstream-UCM6200-Series-WebSocket-1.0.20.20-SQL-Injection.html"
    },
    {
      "source": "vulnreport@tenable.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/research/tra-2020-17"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://packetstormsecurity.com/files/156976/Grandstream-UCM6200-Series-WebSocket-1.0.20.20-SQL-Injection.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/research/tra-2020-17"
    }
  ],
  "sourceIdentifier": "vulnreport@tenable.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "vulnreport@tenable.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…