FKIE_CVE-2020-8601
Vulnerability from fkie_nvd - Published: 2020-02-20 23:15 - Updated: 2024-11-21 05:39
Severity ?
Summary
Trend Micro Vulnerability Protection 2.0 is affected by a vulnerability that could allow an attack to use the product installer to load other DLL files located in the same directory.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trendmicro | vulnerability_protection | 2.0 | |
| microsoft | windows | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trendmicro:vulnerability_protection:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "60A4CFF5-6B1E-4DB7-A1F7-4E8A4F0B9D75",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Trend Micro Vulnerability Protection 2.0 is affected by a vulnerability that could allow an attack to use the product installer to load other DLL files located in the same directory."
},
{
"lang": "es",
"value": "Trend Micro Vulnerability Protection versi\u00f3n 2.0, est\u00e1 afectado por una vulnerabilidad que podr\u00eda permitir que un ataque use el instalador del producto para cargar otros archivos DLL localizados en el mismo directorio."
}
],
"id": "CVE-2020-8601",
"lastModified": "2024-11-21T05:39:06.447",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-02-20T23:15:20.897",
"references": [
{
"source": "security@trendmicro.com",
"tags": [
"Vendor Advisory"
],
"url": "https://success.trendmicro.com/solution/000241963"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://success.trendmicro.com/solution/000241963"
}
],
"sourceIdentifier": "security@trendmicro.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-427"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…