GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2020-8745

Vulnerability from fkie_nvd - Published: 2020-11-12 18:15 - Updated: 2026-06-17 03:26
Summary
Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.
Impacted products
Vendor Product Version
intel converged_security_and_manageability_engine *
intel converged_security_and_manageability_engine *
intel converged_security_and_manageability_engine *
intel converged_security_and_manageability_engine *
intel converged_security_and_manageability_engine *
intel converged_security_and_manageability_engine *
intel trusted_execution_technology *
intel trusted_execution_technology *
siemens simatic_drive_controller_firmware *
siemens simatic_drive_controller -
siemens simatic_et200sp_1515sp_pc2_firmware *
siemens simatic_et200sp_1515sp_pc2 -
siemens simatic_field_pg_m5_firmware *
siemens simatic_field_pg_m5 -
siemens simatic_field_pg_m6_firmware -
siemens simatic_field_pg_m6 -
siemens simatic_ipc127e_firmware *
siemens simatic_ipc127e -
siemens simatic_ipc427e_firmware *
siemens simatic_ipc427e -
siemens simatic_ipc477e_firmware *
siemens simatic_ipc477e -
siemens simatic_ipc477e_pro -
siemens simatic_ipc527g_firmware *
siemens simatic_ipc527g -
siemens simatic_ipc547g_firmware *
siemens simatic_ipc547g -
siemens simatic_ipc627e_firmware *
siemens simatic_ipc627e -
siemens simatic_ipc647e_firmware *
siemens simatic_ipc647e -
siemens simatic_ipc667e_firmware *
siemens simatic_ipc667e -
siemens simatic_ipc847e_firmware *
siemens simatic_ipc847e -
siemens simatic_itp1000_firmware *
siemens simatic_itp1000 -
siemens sinumerik_828d_hw_pu.4_firmware *
siemens sinumerik_828d_hw_pu.4 -
siemens sinumerik_mc_mcu_1720_firmware *
siemens sinumerik_mc_mcu_1720 -
siemens sinumerik_one_firmware -
siemens sinumerik_one -
siemens sinumerik_840d_sl_ht_10_firmware -
siemens sinumerik_840d_sl_ht_10 -
siemens sinumerik_one_ncu_1740_firmware *
siemens sinumerik_one_ncu_1740 -
siemens sinumerik_one_ppu_1740_firmware *
siemens sinumerik_one_ppu_1740 -

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Intel(R) CSME, Intel(R) TXE",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30"
            }
          ]
        }
      ],
      "source": "secure@intel.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA64E7EE-8977-4427-9FF9-DD9FE80F02C6",
              "versionEndExcluding": "11.8.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DDDD0D3-CE11-49C7-93F7-F2AA1053DD86",
              "versionEndExcluding": "11.12.80",
              "versionStartIncluding": "11.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A5C4B3E-3C68-4D2B-A181-18A71378362E",
              "versionEndExcluding": "11.22.80",
              "versionStartIncluding": "11.22.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB22E6F2-D34F-4A05-9CC2-BCAF3E84F54E",
              "versionEndExcluding": "12.0.70",
              "versionStartIncluding": "12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94D40FF5-8E0A-4591-9CE4-2E671C8E4F2E",
              "versionEndExcluding": "14.0.45",
              "versionStartIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B323721-380E-4222-AB7A-9993BF8DA653",
              "versionEndExcluding": "14.5.25",
              "versionStartIncluding": "14.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF1D6613-FA0F-4859-B45C-A0F86BCF1CF8",
              "versionEndExcluding": "3.1.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4BA87F2-F5DE-44A1-B81A-CE1DB5EAFEFA",
              "versionEndExcluding": "4.0.30",
              "versionStartIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA19F1AE-18D4-43F6-BBAB-225B241042BC",
              "versionEndExcluding": "05.00.01.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0137C77B-D587-47D6-AEBE-462D00546FD7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200sp_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC1D3E4-0B86-4464-96BE-D938B379FDAE",
              "versionEndExcluding": "0209.0105",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200sp_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CA8F936-9C3B-46C0-9623-0AF16A4B0294",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5320759-AAAB-4FEA-99AB-51A7F7EE9F58",
              "versionEndExcluding": "22.01.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "161DFB8B-6B7B-4F6D-9452-EF43A70BBE50",
              "versionEndExcluding": "27.01.05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA71050F-CCED-4885-A483-79CC43F6AEC9",
              "versionEndExcluding": "27.01.05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AECF7C4-3FF7-4663-A49C-9DB91BA5C28E",
              "versionEndExcluding": "21.01.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc527g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65A6E7CD-4AEA-465D-89B3-6EF66E4F17B6",
              "versionEndExcluding": "1.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc527g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55156889-E9DA-4F04-B894-339DC39CA942",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA68927-4910-4DF3-A16B-7187099CC063",
              "versionEndExcluding": "r1.30.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9EB339B5-602F-4AB5-9998-465FDC6ABD6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6779ADD8-298D-4FF4-8AD3-82E995B2E144",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3BECCA-5783-4B3C-B659-21160B4D2726",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc667e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6822E36B-D635-498B-9A64-BE427DC798EA",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc667e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E6BC195-47BB-48A7-8D73-F800B4C11599",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C5CB316-59B9-4DDB-A8B8-14D8BCD991CE",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABF49D4-34CE-4DEA-AA2E-A40A53472D1F",
              "versionEndExcluding": "23.01.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_hw_pu.4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC13F580-5446-437D-9982-280C80EAE2D3",
              "versionEndExcluding": "08.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d_hw_pu.4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C594847-596D-4FA2-B56C-745D0A84EBC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_mc_mcu_1720_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF3A945B-078B-45C6-9BA3-3C52650095F1",
              "versionEndExcluding": "05.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF61B283-76B7-42BB-B88A-EE12EA5AA905",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FADF6B2-FFE7-4C4E-BF93-61CAA9368285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE30FFDF-5494-400D-8F88-954A6B1503B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_ht_10_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD5F035E-5F72-4E15-BF13-294C3A833BF7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl_ht_10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14CED950-F0AB-48D1-9ED8-3357E02AEADE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_ncu_1740_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE992410-C477-4901-8B18-8AB866BF11A6",
              "versionEndExcluding": "04.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one_ncu_1740:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0BCDA32-9100-4D88-A304-CE989A16A06D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_ppu_1740_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4A4EDCE-6363-43EB-9CE8-11C0BA40E696",
              "versionEndExcluding": "06.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one_ppu_1740:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75815DC0-5782-4BD6-A9DD-F0BE33D2F5FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
    },
    {
      "lang": "es",
      "value": "Una administraci\u00f3n de flujo de control insuficiente en el subsistema para Intel\u00ae CSME versiones anteriores a 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 y 14.5.25, Intel\u00ae TXE versiones anteriores a 3.1.80 y 4.0.30, pueden habilitar a un usuario no autenticado para permitir potencialmente una escalada de privilegios por medio de un acceso f\u00edsico"
    }
  ],
  "id": "CVE-2020-8745",
  "lastModified": "2026-06-17T03:26:52.540",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-11-12T18:15:17.300",
  "references": [
    {
      "source": "secure@intel.com",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
    }
  ],
  "sourceIdentifier": "secure@intel.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…