FKIE_CVE-2021-36193

Vulnerability from fkie_nvd - Published: 2022-02-02 12:15 - Updated: 2024-11-21 06:13
Summary
Multiple stack-based buffer overflows in the command line interpreter of FortiWeb before 6.4.2 may allow an authenticated attacker to achieve arbitrary code execution via specially crafted commands.
Impacted products
Vendor Product Version
fortinet fortiweb *
fortinet fortiweb *
fortinet fortiweb *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5738C08-6BAE-4A23-895E-CC17152F1ADA",
              "versionEndExcluding": "6.2.6",
              "versionStartIncluding": "5.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0486411-DC71-4C02-8973-B91930A439A2",
              "versionEndExcluding": "6.3.16",
              "versionStartIncluding": "6.3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C97F7E3F-4747-46AA-8D2C-5D7C363CDB14",
              "versionEndExcluding": "6.4.2",
              "versionStartIncluding": "6.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflows in the command line interpreter of FortiWeb before 6.4.2 may allow an authenticated attacker to achieve arbitrary code execution via specially crafted commands."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples desbordamientos de b\u00fafer en la regi\u00f3n stack de la memoria en el int\u00e9rprete de l\u00ednea de comandos de FortiWeb versiones anteriores a 6.4.2, pueden permitir a un atacante autenticado lograr una ejecuci\u00f3n de c\u00f3digo arbitrario por medio de comandos especialmente dise\u00f1ados"
    }
  ],
  "id": "CVE-2021-36193",
  "lastModified": "2024-11-21T06:13:17.667",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "psirt@fortinet.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-02T12:15:07.977",
  "references": [
    {
      "source": "psirt@fortinet.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://fortiguard.com/advisory/FG-IR-21-132"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://fortiguard.com/advisory/FG-IR-21-132"
    }
  ],
  "sourceIdentifier": "psirt@fortinet.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…