FKIE_CVE-2021-3897
Vulnerability from fkie_nvd - Published: 2022-04-22 21:15 - Updated: 2024-11-21 06:22
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
An authentication bypass vulnerability was discovered in an internal service of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware during an that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lenovo:nextscale_n1200_enclosure_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0EAD582C-E91B-4835-AA1B-E5213A407D30",
"versionEndExcluding": "fhet50b-2.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lenovo:nextscale_n1200_enclosure:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21BACC24-DDE4-4016-97DE-60C51E5F1AC6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lenovo:thinkagile_hx_enclosure_certified_node_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6FAD1959-ABD8-425A-BFF9-72855654BFA0",
"versionEndExcluding": "tesm28b-1.21",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lenovo:thinkagile_hx_enclosure_certified_node:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41B43352-1245-46E2-A167-47B2E629BFA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lenovo:thinkagile_vx_enclosure_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AAB1480F-BD40-4C75-AF46-C0AF99B45012",
"versionEndExcluding": "tesm28b-1.21",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lenovo:thinkagile_vx_enclosure:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C425D71A-19B5-4983-B95C-B5CB6EB7C065",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lenovo:thinksystem_d2_enclosure_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E4F65776-CCF4-40A8-934F-E41056A258F5",
"versionEndExcluding": "tesm28b-1.21",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lenovo:thinksystem_d2_enclosure:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8A78D856-B4DF-4B79-9901-434AE6FCE240",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:nextscale_fan_power_controller_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CBA4E681-6674-424F-89F6-7DA9156549F4",
"versionEndExcluding": "44a-3.70",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:nextscale_fan_power_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "493DD621-E61D-42FC-ADB3-0AEA67E873A2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An authentication bypass vulnerability was discovered in an internal service of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware during an that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en un servicio interno del firmware de Lenovo Fan Power Controller2 (FPC2) y Lenovo System Management Module (SMM) durante un que podr\u00eda permitir a un atacante no autenticado ejecutar comandos en el SMM y el FPC2. SMM2 no est\u00e1 afectado"
}
],
"id": "CVE-2021-3897",
"lastModified": "2024-11-21T06:22:43.317",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "psirt@lenovo.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-22T21:15:09.620",
"references": [
{
"source": "psirt@lenovo.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
],
"sourceIdentifier": "psirt@lenovo.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-288"
}
],
"source": "psirt@lenovo.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…