FKIE_CVE-2022-22259
Vulnerability from fkie_nvd - Published: 2022-06-13 19:15 - Updated: 2024-11-21 06:46
Severity ?
Summary
There is an improper authentication vulnerability in FLMG-10 10.0.1.0(H100SP22C00). Successful exploitation of this vulnerability may lead to a control of the victim device.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| huawei | flmg-10_firmware | 10.0.1.0\(h100sp22c00\) | |
| huawei | flmg-10 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:huawei:flmg-10_firmware:10.0.1.0\\(h100sp22c00\\):*:*:*:*:*:*:*",
"matchCriteriaId": "E27482ED-7F44-4840-A132-0627A58468B3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:huawei:flmg-10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A8AC0B1F-0F85-4F9C-BF6A-E8E64BA937A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "There is an improper authentication vulnerability in FLMG-10 10.0.1.0(H100SP22C00). Successful exploitation of this vulnerability may lead to a control of the victim device."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de autenticaci\u00f3n inapropiada en FLMG-10 versi\u00f3n 10.0.1.0(H100SP22C00). Una explotaci\u00f3n con \u00e9xito de esta vulnerabilidad puede conllevar a un control del dispositivo v\u00edctima"
}
],
"id": "CVE-2022-22259",
"lastModified": "2024-11-21T06:46:30.470",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-13T19:15:07.183",
"references": [
{
"source": "psirt@huawei.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20220406-01-bdb62b17-en"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20220406-01-bdb62b17-en"
}
],
"sourceIdentifier": "psirt@huawei.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…