FKIE_CVE-2022-29831
Vulnerability from fkie_nvd - Published: 2022-11-25 00:15 - Updated: 2026-06-17 04:40
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| mitsubishielectric | gx_works3 | * | |
| mitsubishielectric | gx_works3 | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "GX Works3",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.015R to 1.095Z"
}
]
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
"versionEndIncluding": "1.086q",
"versionStartIncluding": "1.015r",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
"versionStartIncluding": "1.087r",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules."
},
{
"lang": "es",
"value": "El uso de la vulnerabilidad de contrase\u00f1a codificada en Mitsubishi Electric Corporation GX Works3 desde la versi\u00f3n 1.015R hasta 1.095Z permite a un atacante remoto no autenticado obtener informaci\u00f3n sobre el archivo de proyecto para los m\u00f3dulos de CPU de seguridad MELSEC."
}
],
"id": "CVE-2022-29831",
"lastModified": "2026-06-17T04:40:47.413",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-29831",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-25T17:49:38.542762Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-11-25T00:15:10.437",
"references": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/vu/JVNVU97244961"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/vu/JVNVU97244961"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
}
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-259"
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…