FKIE_CVE-2022-37302
Vulnerability from fkie_nvd - Published: 2022-09-13 10:15 - Updated: 2024-11-21 07:14
Severity ?
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Summary
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/us/en/download/document/SEVD-2022-221-03/ | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/us/en/download/document/SEVD-2022-221-03/ | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | ecostruxure_control_expert | * | |
| schneider-electric | ecostruxure_control_expert | 15.1 | |
| schneider-electric | ecostruxure_control_expert | 15.1 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314",
"versionEndExcluding": "15.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*",
"matchCriteriaId": "78F6B1CC-488B-48E8-B96B-77A1894E9E92",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:hf001:*:*:*:*:*:*",
"matchCriteriaId": "957D54EF-4337-4DA6-AAA7-FE1905153A75",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior)."
},
{
"lang": "es",
"value": "Una CWE-119: Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los L\u00edmites de un B\u00fafer de Memoria que podr\u00eda causar un bloqueo del software Control Expert cuando es abierto un archivo de proyecto incorrecto. Productos afectados: EcoStruxure Control Expert (versiones V15.1 HF001 y anteriores)"
}
],
"id": "CVE-2022-37302",
"lastModified": "2024-11-21T07:14:42.920",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-09-13T10:15:10.847",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/us/en/download/document/SEVD-2022-221-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/us/en/download/document/SEVD-2022-221-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…