FKIE_CVE-2023-45209
Vulnerability from fkie_nvd - Published: 2024-04-17 13:15 - Updated: 2025-11-04 19:15
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
An information disclosure vulnerability exists in the web interface /cgi-bin/download_config.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| peplink | smart_reader_firmware | 1.2.0 | |
| peplink | smart_reader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:peplink:smart_reader_firmware:1.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "EC88FE9B-A7C2-4EAD-9830-65E07911BE83",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:peplink:smart_reader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07C8582C-3B8B-453C-A7AD-7567F905377D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in the web interface /cgi-bin/download_config.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en la funcionalidad de la interfaz web /cgi-bin/download_config.cgi de Peplink Smart Reader v1.2.0 (en QEMU). Una solicitud HTTP especialmente manipulada puede dar lugar a la divulgaci\u00f3n de informaci\u00f3n confidencial. Un atacante puede realizar una solicitud HTTP no autenticada para desencadenar esta vulnerabilidad."
}
],
"id": "CVE-2023-45209",
"lastModified": "2025-11-04T19:15:59.927",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-04-17T13:15:07.633",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://forum.peplink.com/t/peplink-security-advisory-smart-reader-firmware-1-2-0-cve-2023-43491-cve-2023-45209-cve-2023-39367-cve-2023-45744-cve-2023-40146/47256"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1865"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://forum.peplink.com/t/peplink-security-advisory-smart-reader-firmware-1-2-0-cve-2023-43491-cve-2023-45209-cve-2023-39367-cve-2023-45744-cve-2023-40146/47256"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1865"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1865"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…