FKIE_CVE-2023-5407

Vulnerability from fkie_nvd - Published: 2024-04-17 17:15 - Updated: 2026-06-17 06:48
Summary
Controller denial of service due to improper handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgrading and versioning.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Experion PKS"
          ],
          "product": "C300",
          "vendor": "Honeywell",
          "versions": [
            {
              "changes": [
                {
                  "at": "520.2 TCU4 HF1",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "520.2 TCU4",
              "status": "affected",
              "version": "520.2",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "510.2 HF14",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "510.2 HF13",
              "status": "affected",
              "version": "510.1",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "520.1 TCU5",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "520.1 TCU4",
              "status": "affected",
              "version": "520.1",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "511.5 TCU4 HF4",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "511.5 TCU4 HF3",
              "status": "affected",
              "version": "511.1",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Experion LX"
          ],
          "product": "C300",
          "vendor": "Honeywell",
          "versions": [
            {
              "changes": [
                {
                  "at": "520.2 TCU4 HF2",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "520.2 TCU4",
              "status": "affected",
              "version": "520.2",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "511.5 TCU4 HF4",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "511.5 TCU4 HF3",
              "status": "affected",
              "version": "511.1",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "520.1 TCU5",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "520.1 TCU4",
              "status": "affected",
              "version": "520.1",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "PlantCruise by Experion"
          ],
          "product": "C300",
          "vendor": "Honeywell",
          "versions": [
            {
              "changes": [
                {
                  "at": "520.2 TCU4 HF2",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "520.2 TCU4",
              "status": "affected",
              "version": "520.2",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "520.1 TCU5",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "520.1 TCU4",
              "status": "affected",
              "version": "520.1",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "511.5 TCU4 HF4",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "511.5 TCU4 HF3",
              "status": "affected",
              "version": "520.2 TCU4 HFR2",
              "versionType": "semver"
            }
          ]
        }
      ],
      "source": "psirt@honeywell.com"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Controller denial of service due to improper handling of a specially crafted message received by the controller.\n\nSee Honeywell Security Notification for recommendations on upgrading and versioning."
    },
    {
      "lang": "es",
      "value": "Denegaci\u00f3n de servicio del controlador debido al manejo inadecuado de un mensaje especialmente manipulado recibido por el controlador. Consulte la Notificaci\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\u00f3n y control de versiones."
    }
  ],
  "id": "CVE-2023-5407",
  "lastModified": "2026-06-17T06:48:31.910",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "psirt@honeywell.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-5407",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2024-04-24T14:30:38.880683Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2024-04-17T17:15:14.650",
  "references": [
    {
      "source": "psirt@honeywell.com",
      "url": "https://process.honeywell.com"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://process.honeywell.com"
    }
  ],
  "sourceIdentifier": "psirt@honeywell.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "psirt@honeywell.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…