FKIE_CVE-2024-21757

Vulnerability from fkie_nvd - Published: 2024-08-13 16:15 - Updated: 2024-08-22 14:34
Summary
A unverified password change in Fortinet FortiManager versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, as well as Fortinet FortiAnalyzer versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, allows an attacker to modify admin passwords via the device configuration backup.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5275A3C-5468-424E-B3BB-897221D2B8D5",
              "versionEndExcluding": "7.0.11",
              "versionStartIncluding": "7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F3D28A9-5CFD-4838-9630-D6E09FB63CE1",
              "versionEndExcluding": "7.2.5",
              "versionStartIncluding": "7.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB15106A-8295-4A9E-B5C8-FA9654636B15",
              "versionEndExcluding": "7.4.2",
              "versionStartIncluding": "7.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B1EF673-5967-401E-98E3-B7A2B1BEF037",
              "versionEndExcluding": "7.0.11",
              "versionStartIncluding": "7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4763E504-6974-42C5-B912-3E62A9CC312A",
              "versionEndExcluding": "7.2.5",
              "versionStartIncluding": "7.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83316FAF-C5DE-4603-B3B2-6796E2FAF1A8",
              "versionEndExcluding": "7.4.2",
              "versionStartIncluding": "7.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A unverified password change in Fortinet FortiManager versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, as well as Fortinet FortiAnalyzer versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, allows an attacker to modify admin passwords via the device configuration backup."
    },
    {
      "lang": "es",
      "value": "Un cambio de contrase\u00f1a no verificado en Fortinet FortiManager versiones 7.0.0 a 7.0.10, versiones 7.2.0 a 7.2.4 y versiones 7.4.0 a 7.4.1, as\u00ed como Fortinet FortiAnalyzer versiones 7.0.0 a 7.0.10, versiones 7.2.0 a 7.2.4 y las versiones 7.4.0 a 7.4.1 permiten a un atacante modificar las contrase\u00f1as de administrador a trav\u00e9s de la copia de seguridad de la configuraci\u00f3n del dispositivo."
    }
  ],
  "id": "CVE-2024-21757",
  "lastModified": "2024-08-22T14:34:54.550",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 4.2,
        "source": "psirt@fortinet.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-08-13T16:15:08.637",
  "references": [
    {
      "source": "psirt@fortinet.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://fortiguard.fortinet.com/psirt/FG-IR-23-467"
    }
  ],
  "sourceIdentifier": "psirt@fortinet.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-620"
        }
      ],
      "source": "psirt@fortinet.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…