FKIE_CVE-2024-2977

Vulnerability from fkie_nvd - Published: 2024-03-27 14:15 - Updated: 2025-01-15 18:19
Summary
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
tenda f1203_firmware 2.0.1.6
tenda f1203 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad en Tenda F1203 2.0.1.6. Ha sido calificada como cr\u00edtica. La funci\u00f3n formQuickIndex del archivo /goform/QuickIndex es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento PPPOEPassword provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-258146 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2024-2977",
  "lastModified": "2025-01-15T18:19:41.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-03-27T14:15:13.000",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.258146"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.258146"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.301028"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.258146"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.258146"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.301028"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…