FKIE_CVE-2024-35520
Vulnerability from fkie_nvd - Published: 2024-10-14 22:15 - Updated: 2024-10-16 17:14
Severity ?
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Netgear R7000 1.0.11.136 is vulnerable to Command Injection in RMT_invite.cgi via device_name2 parameter.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | r7000_firmware | 1.0.11.136 | |
| netgear | r7000 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000_firmware:1.0.11.136:*:*:*:*:*:*:*",
"matchCriteriaId": "746C88B1-7D36-49AA-8A00-1C6108846C27",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Netgear R7000 1.0.11.136 is vulnerable to Command Injection in RMT_invite.cgi via device_name2 parameter."
},
{
"lang": "es",
"value": "Netgear R7000 1.0.11.136 es vulnerable a la inyecci\u00f3n de comandos en RMT_invite.cgi a trav\u00e9s del par\u00e1metro device_name2."
}
],
"id": "CVE-2024-35520",
"lastModified": "2024-10-16T17:14:31.443",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-10-14T22:15:03.727",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://kb.netgear.com/000066027/Security-Advisory-for-Post-Authentication-Command-Injection-on-the-R7000-PSV-2023-0154"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…