FKIE_CVE-2024-5143
Vulnerability from fkie_nvd - Published: 2024-05-23 17:15 - Updated: 2026-01-26 13:53
Severity ?
Summary
A user with device administrative privileges can change existing SMTP server settings on the device, without having to re-enter SMTP server credentials. By redirecting send-to-email traffic to the new server, the original SMTP server credentials may potentially be exposed.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hp | w1a75a_firmware | * | |
| hp | w1a75a | - | |
| hp | w1a76a_firmware | * | |
| hp | w1a76a | - | |
| hp | w1a77a_firmware | * | |
| hp | w1a77a | - | |
| hp | w1a81a_firmware | * | |
| hp | w1a81a | - | |
| hp | w1a82a_firmware | * | |
| hp | w1a82a | - | |
| hp | w1a79a_firmware | * | |
| hp | w1a79a | - | |
| hp | w1a80a_firmware | * | |
| hp | w1a80a | - | |
| hp | w1a78a_firmware | * | |
| hp | w1a78a | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a75a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5D159DAD-72AD-4F21-AF57-F83B213C169A",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a75a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FBE9436-340F-4428-91CB-4F53764AC184",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a76a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2D9E9E0E-A181-4733-BDD1-3F0B2A7A31AF",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a76a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C84C74A6-597E-4E0A-93AC-94EF3073321E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a77a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F1645A2E-9718-4A11-ACB1-B6BFCB0BF3AA",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a77a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76B034FA-D338-40CD-917E-7B8177715FCB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a81a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B27C3D9B-1370-4A0B-96BF-8D90974752A7",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a81a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF8D6946-CE0F-45AE-BBA9-5983F860FEDD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a82a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F19D28D7-0E4A-4789-B1F5-814FFCB928CC",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a82a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E35167E-1A40-4A62-931B-6AF8F49C2214",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a79a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B33F043A-48FE-4BBE-89F0-5165E6984739",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a79a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "81B33E5A-E22E-4DCF-9B8E-F0650CBF6309",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a80a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09F39E93-BBE3-4BAC-9016-95D4BE41880A",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a80a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E611AC6F-F279-427F-8213-1B3A1F0EB63B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:w1a78a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DF8738F-A97F-4C6B-9F66-9ABAE062286A",
"versionEndExcluding": "002_2413A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:w1a78a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A103FF3D-FB16-463F-9913-49EEDCDB9348",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A user with device administrative privileges can change existing SMTP server settings on the device, without having to re-enter SMTP server credentials. By redirecting send-to-email traffic to the new server, the original SMTP server credentials may potentially be exposed."
},
{
"lang": "es",
"value": "Un usuario con privilegios administrativos del dispositivo puede cambiar la configuraci\u00f3n del servidor SMTP existente en el dispositivo, sin tener que volver a ingresar las credenciales del servidor SMTP. Al redirigir el tr\u00e1fico de env\u00edo a correo electr\u00f3nico al nuevo servidor, es posible que las credenciales originales del servidor SMTP queden expuestas."
}
],
"id": "CVE-2024-5143",
"lastModified": "2026-01-26T13:53:04.387",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 4.0,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-05-23T17:15:31.560",
"references": [
{
"source": "hp-security-alert@hp.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hp.com/us-en/document/ish_10643804-10643841-16/HPSBPI03941"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hp.com/us-en/document/ish_10643804-10643841-16/HPSBPI03941"
}
],
"sourceIdentifier": "hp-security-alert@hp.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…