FKIE_CVE-2025-26336

Vulnerability from fkie_nvd - Published: 2025-03-21 03:15 - Updated: 2026-06-17 09:01
Summary
Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.40.200.202101130302",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dell Chassis Management Controller (CMC) for PowerEdge VRTX",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "3.41.200.202209300499",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "source": "security_alert@emc.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:chassis_management_controller_for_poweredge_fx2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86DEA45C-1FE5-49A0-A4F3-DCC9C2E96F9F",
              "versionEndExcluding": "2.40.200.202101130302",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dell:chassis_management_controller_for_poweredge_fx2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85DD85AB-A95E-4CF3-8C08-BC939D9B2DD2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:chassis_management_controller_for_poweredge_vrtx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C173E0A-300A-418A-A8CC-48A48759F0A9",
              "versionEndExcluding": "3.41.200.202209300499",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dell:chassis_management_controller_for_poweredge_vrtx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0F3696A-54A0-4BAD-B8A1-E0D54E4C2A84",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."
    },
    {
      "lang": "es",
      "value": "Dell Chassis Management Controller Firmware para Dell PowerEdge FX2, versiones anteriores a la 2.40.200.202101130302, y Dell Chassis Management Controller Firmware para Dell PowerEdge VRTX, versiones anteriores a la 3.41.200.202209300499, presentan una vulnerabilidad de desbordamiento de b\u00fafer basado en pila. Un atacante no autenticado con acceso remoto podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda una ejecuci\u00f3n remota."
    }
  ],
  "id": "CVE-2025-26336",
  "lastModified": "2026-06-17T09:01:36.023",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.5,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-26336",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-03-21T13:59:37.293545Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2025-03-21T03:15:12.000",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000297463/dsa-2025-123-security-update-for-dell-chassis-management-controller-firmware-for-dell-poweredge-fx2-and-vrtx-vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…