FKIE_CVE-2025-29987
Vulnerability from fkie_nvd - Published: 2025-04-03 16:15 - Updated: 2025-04-07 14:18
Severity ?
Summary
Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges."
},
{
"lang": "es",
"value": "Las versiones de Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) anteriores a la 8.3.0.15 presentan una vulnerabilidad de control de acceso con granularidad insuficiente. Un usuario autenticado de un cliente remoto de confianza podr\u00eda aprovechar esta vulnerabilidad para ejecutar comandos arbitrarios con privilegios de root."
}
],
"id": "CVE-2025-29987",
"lastModified": "2025-04-07T14:18:34.453",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
},
"published": "2025-04-03T16:15:36.420",
"references": [
{
"source": "security_alert@emc.com",
"url": "https://www.dell.com/support/kbdoc/en-us/000300899/dsa-2025-139-dell-technologies-powerprotect-data-domain-security-update-for-a-security-vulnerability"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1220"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…