FKIE_CVE-2025-4142
Vulnerability from fkie_nvd - Published: 2025-04-30 23:16 - Updated: 2025-05-12 19:39
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. This vulnerability affects the function sub_3C8EC. The manipulation of the argument host leads to buffer overflow. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://github.com/jylsec/vuldb/blob/main/Netgear/netgear_ex6200/Buffer_overflow-sub_3C8EC-gui_Wireless_Security_state/README.md | Exploit | |
| cna@vuldb.com | https://vuldb.com/?ctiid.306634 | Permissions Required, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.306634 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?submit.560790 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://www.netgear.com/ | Product |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | ex6200_firmware | 1.0.3.94 | |
| netgear | ex6120 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6200_firmware:1.0.3.94:*:*:*:*:*:*:*",
"matchCriteriaId": "E7B6521D-DFB6-47BF-8D4C-559763C56C9F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. This vulnerability affects the function sub_3C8EC. The manipulation of the argument host leads to buffer overflow. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad en Netgear EX6200 1.0.3.94, clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n sub_3C8EC. La manipulaci\u00f3n del argumento \"host\" provoca un desbordamiento del b\u00fafer. El ataque puede iniciarse remotamente. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta vulnerabilidad, pero no respondi\u00f3."
}
],
"id": "CVE-2025-4142",
"lastModified": "2025-05-12T19:39:50.053",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
},
"published": "2025-04-30T23:16:02.543",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Exploit"
],
"url": "https://github.com/jylsec/vuldb/blob/main/Netgear/netgear_ex6200/Buffer_overflow-sub_3C8EC-gui_Wireless_Security_state/README.md"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.306634"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.306634"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.560790"
},
{
"source": "cna@vuldb.com",
"tags": [
"Product"
],
"url": "https://www.netgear.com/"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
},
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "cna@vuldb.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…