FKIE_CVE-2026-22281
Vulnerability from fkie_nvd - Published: 2026-01-22 20:16 - Updated: 2026-01-28 18:14
Severity ?
3.5 (Low) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
4.8 (Medium) - CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H
4.8 (Medium) - CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Dell PowerScale OneFS, versions 9.5.0.0 through 9.5.1.5, versions 9.6.0.0 through 9.7.1.10, versions 9.8.0.0 through 9.10.1.3, versions starting from 9.11.0.0 and prior to 9.13.0.0, contains a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to denial of service.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | powerscale_onefs | * | |
| dell | powerscale_onefs | * | |
| dell | powerscale_onefs | * | |
| dell | powerscale_onefs | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
"matchCriteriaId": "75F87F94-D52B-4D81-89A7-CBE5AEFEBA5A",
"versionEndExcluding": "9.5.1.6",
"versionStartIncluding": "9.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8E921D4F-223E-4630-897F-B55D2B1E06A7",
"versionEndExcluding": "9.7.1.11",
"versionStartIncluding": "9.6.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80A6C071-87C3-40C6-8C26-F6D239A77388",
"versionEndExcluding": "9.10.1.4",
"versionStartIncluding": "9.8.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9019F2DB-1449-4315-85CB-A35BB2AEF4BB",
"versionEndExcluding": "9.13.0.0",
"versionStartIncluding": "9.11.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerScale OneFS, versions 9.5.0.0 through 9.5.1.5, versions 9.6.0.0 through 9.7.1.10, versions 9.8.0.0 through 9.10.1.3, versions starting from 9.11.0.0 and prior to 9.13.0.0, contains a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to denial of service."
}
],
"id": "CVE-2026-22281",
"lastModified": "2026-01-28T18:14:09.367",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 1.4,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2026-01-22T20:16:13.257",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000415586/dsa-2026-049-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-367"
}
],
"source": "security_alert@emc.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…