GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2026-24437

Vulnerability from fkie_nvd - Published: 2026-01-26 18:16 - Updated: 2026-06-17 10:23
Summary
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access.
Impacted products
Vendor Product Version
tenda w30e_firmware *
tenda w30e 2.0

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unknown",
          "product": "W30E V2",
          "vendor": "Shenzhen Tenda Technology Co., Ltd.",
          "versions": [
            {
              "lessThanOrEqual": "16.01.0.19(5037)",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "disclosure@vulncheck.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:w30e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DB07B19-71FC-4936-98BD-36A8B3B7CBF0",
              "versionEndIncluding": "16.01.0.19\\(5037\\)",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:w30e:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "56B9C2BB-D36E-40F8-83FF-FC919337F6BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de Shenzhen Tenda W30E V2 hasta e incluyendo la V16.01.0.19(5037) sirven contenido administrativo sensible sin directivas de control de cach\u00e9 apropiadas. Como resultado, los navegadores pueden almacenar localmente respuestas que contienen credenciales, exponi\u00e9ndolas a un acceso no autorizado posterior."
    }
  ],
  "id": "CVE-2026-24437",
  "lastModified": "2026-06-17T10:23:04.600",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "NONE",
          "vulnConfidentialityImpact": "LOW",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-24437",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-01-26T21:06:40.408833Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2026-01-26T18:16:41.317",
  "references": [
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tendacn.com/product/W30E"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.vulncheck.com/advisories/tenda-w30e-v2-missing-cache-controls-for-credential-bearing-pages"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-525"
        }
      ],
      "source": "disclosure@vulncheck.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…