FKIE_CVE-2026-71925

Vulnerability from fkie_nvd - Published: 2026-08-24 18:17 - Updated: 2026-08-26 17:08
Summary
Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2540xs",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "3.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2540xs",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "3.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch FX2120",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "3.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2282x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.10.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2282x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.10.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch Q2300x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.10.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch PQ2300xb",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.10.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2542x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "3.10.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2542x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "3.10.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2542xh",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "3.10.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch PX2060",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G1280",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P1280",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P1281x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G1282",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P1282",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2121",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2121",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch PQ2121x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch Q2121x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2280x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2280x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch Q2200x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch PQ2200xb",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2100",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2100",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch G2540x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VigorSwitch P2540x",
          "vendor": "DrayTek Corporation",
          "versions": [
            {
              "lessThan": "2.9.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "disclosure@vulncheck.com"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device\u0027s web management interface."
    }
  ],
  "id": "CVE-2026-71925",
  "lastModified": "2026-08-26T17:08:22.300",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "HIGH",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-71925",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-08-24T18:32:28.878728Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2026-08-24T18:17:07.813",
  "references": [
    {
      "source": "disclosure@vulncheck.com",
      "url": "https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/"
    },
    {
      "source": "disclosure@vulncheck.com",
      "url": "https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-os-command-injection-via-getdetail"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "disclosure@vulncheck.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…