Details

A vulnerability in Cisco Intelligent Node (iNode) Software could allow an unauthenticated, remote attacker to hijack the TLS connection between Cisco iNode Manager and associated intelligent nodes and send arbitrary traffic to an affected device.

This vulnerability is due to the presence of hard-coded cryptographic material. An attacker in a man-in-the-middle position between Cisco iNode Manager and associated deployed nodes could exploit this vulnerability by using the static cryptographic key to generate a trusted certificate and impersonate an affected device. A successful exploit could allow the attacker to read data that is meant for a legitimate device, modify the startup configuration of an associated node, and, consequently, cause a denial of service (DoS) condition for downstream devices that are connected to the affected node.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2024-20323"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-321"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-07-17T17:15:12Z",
    "severity": "HIGH"
  },
  "details": "A vulnerability in Cisco Intelligent Node (iNode) Software could allow an unauthenticated, remote attacker to hijack the TLS connection between Cisco iNode Manager and associated intelligent nodes and send arbitrary traffic to an affected device.\n\n This vulnerability is due to the presence of hard-coded cryptographic material. An attacker in a man-in-the-middle position between Cisco iNode Manager and associated deployed nodes could exploit this vulnerability by using the static cryptographic key to generate a trusted certificate and impersonate an affected device. A successful exploit could allow the attacker to read data that is meant for a legitimate device, modify the startup configuration of an associated node, and, consequently, cause a denial of service (DoS) condition for downstream devices that are connected to the affected node.",
  "id": "GHSA-82vj-crx8-gvp9",
  "modified": "2024-07-17T18:31:00Z",
  "published": "2024-07-17T18:31:00Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-20323"
    },
    {
      "type": "WEB",
      "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-inode-static-key-VUVCeynn"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:N",
      "type": "CVSS_V3"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.