GHSA-HPJG-HQR4-WGGC

Vulnerability from github – Published: 2023-06-28 15:30 – Updated: 2023-06-28 15:30
VLAI?
Details

A vulnerability in the web-based management interface of Cisco Small Business 200 Series Smart Switches, Cisco Small Business 300 Series Managed Switches, and Cisco Small Business 500 Series Stackable Managed Switches could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by persuading a user of an affected interface to view a page containing malicious HTML or script content. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. To exploit this vulnerability, the attacker would need to have valid credentials to access the web-based management interface of the affected device. Cisco has not released software updates to address this vulnerability.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2023-20188"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-79",
      "CWE-87"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2023-06-28T15:15:09Z",
    "severity": "MODERATE"
  },
  "details": "A vulnerability in the web-based management interface of Cisco Small Business 200 Series Smart Switches, Cisco Small Business 300 Series Managed Switches, and Cisco Small Business 500 Series Stackable Managed Switches could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by persuading a user of an affected interface to view a page containing malicious HTML or script content. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. To exploit this vulnerability, the attacker would need to have valid credentials to access the web-based management interface of the affected device. Cisco has not released software updates to address this vulnerability.",
  "id": "GHSA-hpjg-hqr4-wggc",
  "modified": "2023-06-28T15:30:23Z",
  "published": "2023-06-28T15:30:23Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-20188"
    },
    {
      "type": "WEB",
      "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-smb-sxss-OPYJZUmE"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
      "type": "CVSS_V3"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…