ghsa-q5h2-62hm-664w
Vulnerability from github
A vulnerability in the web-based management interface of Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack and alter the data of existing users and groups on an affected device. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. If the user has administrative privileges, the attacker could create a new, privileged account to obtain full control over the device interface. This vulnerability affects Connected Grid Network Management System, if running a software release prior to IoT-FND Release 3.0; and IoT Field Network Director, if running a software release prior to IoT-FND Release 4.1.1-6 or 4.2.0-123. Cisco Bug IDs: CSCvi02448.
{ "affected": [], "aliases": [ "CVE-2018-0270" ], "database_specific": { "cwe_ids": [ "CWE-352" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-05-17T03:29:00Z", "severity": "HIGH" }, "details": "A vulnerability in the web-based management interface of Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack and alter the data of existing users and groups on an affected device. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. If the user has administrative privileges, the attacker could create a new, privileged account to obtain full control over the device interface. This vulnerability affects Connected Grid Network Management System, if running a software release prior to IoT-FND Release 3.0; and IoT Field Network Director, if running a software release prior to IoT-FND Release 4.1.1-6 or 4.2.0-123. Cisco Bug IDs: CSCvi02448.", "id": "GHSA-q5h2-62hm-664w", "modified": "2022-05-13T01:35:29Z", "published": "2022-05-13T01:35:29Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-0270" }, { "type": "WEB", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-fnd" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/104242" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.