Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2017-5242",
    "id": "GSD-2017-5242"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2017-5242"
      ],
      "details": "Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots.",
      "id": "GSD-2017-5242",
      "modified": "2023-12-13T01:21:14.024582Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@rapid7.com",
        "DATE_PUBLIC": "2017-08-19T10:10:00.000Z",
        "ID": "CVE-2017-5242",
        "STATE": "PUBLIC",
        "TITLE": "Rapid7 Nexpose Virtual Appliance Duplicate SSH Host Key"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Nexpose Virtual Appliance",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003e=",
                          "version_name": "2017.04.05",
                          "version_value": "2017.04.05"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "2017.05.03",
                          "version_value": "2017.05.03"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "InsightVM Virtual Appliance",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003e=",
                          "version_name": "2017.04.05",
                          "version_value": "2017.04.05"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "2017.05.03",
                          "version_value": "2017.05.03"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Rapid7"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-321 Use of Hard-coded Cryptographic Key"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.rapid7.com/blog/post/2017/05/17/rapid7-nexpose-virtual-appliance-duplicate-ssh-host-key-cve-2017-5242/",
            "refsource": "CONFIRM",
            "url": "https://www.rapid7.com/blog/post/2017/05/17/rapid7-nexpose-virtual-appliance-duplicate-ssh-host-key-cve-2017-5242/"
          }
        ]
      },
      "source": {
        "discovery": "INTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:rapid7:insightvm:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2017-05-03",
                "versionStartIncluding": "2017-04-05",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5242"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-330"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.rapid7.com/blog/post/2017/05/17/rapid7-nexpose-virtual-appliance-duplicate-ssh-host-key-cve-2017-5242/",
              "refsource": "CONFIRM",
              "tags": [
                "Mitigation",
                "Vendor Advisory"
              ],
              "url": "https://www.rapid7.com/blog/post/2017/05/17/rapid7-nexpose-virtual-appliance-duplicate-ssh-host-key-cve-2017-5242/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 1.3,
          "impactScore": 5.8
        }
      },
      "lastModifiedDate": "2023-01-23T17:47Z",
      "publishedDate": "2023-01-12T22:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…