GSD-2017-6650
Vulnerability from gsd - Updated: 2023-12-13 01:21Details
A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user's privilege level outside of the user's path. Cisco Bug IDs: CSCvb86771.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2017-6650",
"description": "A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user\u0027s privilege level outside of the user\u0027s path. Cisco Bug IDs: CSCvb86771.",
"id": "GSD-2017-6650"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2017-6650"
],
"details": "A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user\u0027s privilege level outside of the user\u0027s path. Cisco Bug IDs: CSCvb86771.",
"id": "GSD-2017-6650",
"modified": "2023-12-13T01:21:09.759377Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2017-6650",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Nexus Series Switches",
"version": {
"version_data": [
{
"version_value": "Cisco Nexus Series Switches"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user\u0027s privilege level outside of the user\u0027s path. Cisco Bug IDs: CSCvb86771."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1038518",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038518"
},
{
"name": "98528",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98528"
},
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170517-nss1",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170517-nss1"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.2\\(0\\)zz\\(99.1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(3\\)n1\\(3.12\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.2\\(1\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(3\\)n1\\(2.1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.2\\(0\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.3\\(0\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(3\\)n1\\(2\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.2\\(0\\)d1\\(0.437\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(3\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(4\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(2\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:nx-os:7.1\\(1\\)n1\\(1\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5672up-16g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5648q:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5596up:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5548up:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5624q:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5596t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5696q:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_5672up:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:nexus_56128p:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2017-6650"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user\u0027s privilege level outside of the user\u0027s path. Cisco Bug IDs: CSCvb86771."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
},
{
"lang": "en",
"value": "CWE-77"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170517-nss1",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170517-nss1"
},
{
"name": "98528",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"Vendor Advisory"
],
"url": "http://www.securityfocus.com/bid/98528"
},
{
"name": "1038518",
"refsource": "SECTRACK",
"tags": [],
"url": "http://www.securitytracker.com/id/1038518"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2019-10-03T00:03Z",
"publishedDate": "2017-05-22T01:29Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…