GSD-2018-0453
Vulnerability from gsd - Updated: 2023-12-13 01:22Details
A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2018-0453",
"description": "A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC.",
"id": "GSD-2018-0453"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2018-0453"
],
"details": "A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC.",
"id": "GSD-2018-0453",
"modified": "2023-12-13T01:22:24.884331Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2018-10-03T16:00:00-0500",
"ID": "CVE-2018-0453",
"STATE": "PUBLIC",
"TITLE": "Cisco Firepower Management Center and Firepower System Software Sourcefire Tunnel Control Channel Command Execution Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco FireSIGHT System Software ",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC."
}
]
},
"impact": {
"cvss": {
"baseScore": "8.2",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-264"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20181003 Cisco Firepower Management Center and Firepower System Software Sourcefire Tunnel Control Channel Command Execution Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181003-fp-cmd-injection"
}
]
},
"source": {
"advisory": "cisco-sa-20181003-fp-cmd-injection",
"defect": [
[
"CSCvg46466"
]
],
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:6.0.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:6.2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:6.2.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:6.2.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:6.0.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:6.1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:5.4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2018-0453"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20181003 Cisco Firepower Management Center and Firepower System Software Sourcefire Tunnel Control Channel Command Execution Vulnerability",
"refsource": "CISCO",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181003-fp-cmd-injection"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.5,
"impactScore": 6.0
}
},
"lastModifiedDate": "2019-10-09T23:32Z",
"publishedDate": "2018-10-05T14:29Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…