A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2018-13799",
    "description": "A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions \u003c V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.",
    "id": "GSD-2018-13799"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2018-13799"
      ],
      "details": "A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions \u003c V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.",
      "id": "GSD-2018-13799",
      "modified": "2023-12-13T01:22:27.133722Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "DATE_PUBLIC": "2018-09-11T00:00:00",
        "ID": "CVE-2018-13799",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "SIMATIC WinCC OA V3.14 and prior",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "SIMATIC WinCC OA V3.14 and prior : All versions \u003c V3.14-P021"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens AG"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions \u003c V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-269: Improper Privilege Management"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "105332",
            "refsource": "BID",
            "url": "http://www.securityfocus.com/bid/105332"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-346256.pdf",
            "refsource": "CONFIRM",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346256.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "3.14",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-13799"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions \u003c V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-noinfo"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-346256.pdf",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346256.pdf"
            },
            {
              "name": "105332",
              "refsource": "BID",
              "tags": [
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "http://www.securityfocus.com/bid/105332"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 4.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.2
        }
      },
      "lastModifiedDate": "2019-10-09T23:34Z",
      "publishedDate": "2018-09-12T13:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.