gsd-2018-2566
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.0 Base Score 7.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N).
Aliases
Aliases
{ "GSD": { "alias": "CVE-2018-2566", "description": "Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.0 Base Score 7.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N).", "id": "GSD-2018-2566" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-2566" ], "details": "Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.0 Base Score 7.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N).", "id": "GSD-2018-2566", "modified": "2023-12-13T01:22:32.043678Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "secalert_us@oracle.com", "ID": "CVE-2018-2566", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SSM - (hot-tamale) ILOM: Integrated Lights Out Manager", "version": { "version_data": [ { "version_affected": "=", "version_value": "3.x" }, { "version_affected": "=", "version_value": "4.x" } ] } } ] }, "vendor_name": "Oracle Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.0 Base Score 7.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data." } ] } ] }, "references": { "reference_data": [ { "name": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html", "refsource": "CONFIRM", "url": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html" }, { "name": "102603", "refsource": "BID", "url": "http://www.securityfocus.com/bid/102603" }, { "name": "1040205", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1040205" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:4.0.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.16:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.10:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.12:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.14:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:4.0.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:4.0.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "secalert_us@oracle.com", "ID": "CVE-2018-2566" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.0 Base Score 7.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html", "refsource": "CONFIRM", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html" }, { "name": "1040205", "refsource": "SECTRACK", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securitytracker.com/id/1040205" }, { "name": "102603", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/102603" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 4.9, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, "exploitabilityScore": 1.3, "impactScore": 5.8 } }, "lastModifiedDate": "2019-10-03T00:03Z", "publishedDate": "2018-01-18T02:29Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.